Inulin measurement in serum and urine with an autoanalyser, corrected for glucose interference.
نویسندگان
چکیده
A method is described for the semi-automated measurement of inulin concentrations in serum and urine in the presence of glucose. The concentration of glucose is measured simultaneously and is used to correct for almost all "inulin-like" interferences. The inulin standard curve is linear over a wide range (5-2500 mg/l). Between-run precision is < 6% and recovery from spiked sera is 98%. This method offers the possibility of measuring glomerular filtration rate in patients with varying glucose concentrations (e.g. diabetics).
منابع مشابه
[Measurement of inulin: development].
Inulin clearance is still considered as the gold standard method to measure glomerular filtration rate. This method has been proposed in thirties by Smith and Shannon but the inulin measurement method still remains complex. Interferences, notably with the glucose, must also be considered. Two main methods have been proposed to measure inulin both in urine and plasma: "acid" or enzymatic methods...
متن کاملElimination of glucose interference and improved precision in a continuous-flow analysis for inulin.
A modified fermentation procedure based on one described by Homer Smith in his textbook was used to eliminate glucose interference in the automated detrmination of inulin. The manifold of Fjeldbo and Stamey [J. Lab. Clin. Med. 72, 353 (1968)] was modified to enable us to insert the fermentation procedure without sacrificing precision in continuous-flow analysis for inulin. Analytical recoveries...
متن کاملAn antomated method for the quantitative assessment of low concentrations of glucose in urine.
In view of the recent work by Schersten and Fritz (1967), which indicates that the utilization of small amounts of glucose in urine by actively respiring bacteria can be used as an index of urinary tract infection, there is a need for a simple, sensitive test which detects very low concentration of urine glucose and can be applied in the analysis of large numbers of specimens. This paper descri...
متن کاملMeasurement of hexoses and pentoses, singly or in combination, with o-anisidine.
Hexoses and pentoses can be measured either singly or in combination, with an o-anisidine reagent. It has the advantages of a fastreactionrateand relativelylittle interference from hexoses (Amax = 660 nm) in the measurement of pentoses. A simple subtraction of absorbance attributable to glucose at the maximum for pentoses (465 nm) is sufficient for satisfactory pentose estimation in urine. The ...
متن کاملEvaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease
Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies
دوره 32 8 شماره
صفحات -
تاریخ انتشار 1994