Impact of Active Power Curtailment on Overvoltage Prevention and Energy Production of PV Inverters Connected to Low Voltage Residential Feeders

نویسندگان

  • Reinaldo Tonkoski
  • Luiz A. C. Lopes
چکیده

As non-controllable power sources, photovoltaics (PV) can create overvoltage in low voltage (LV) distribution feeders during periods of high generation and low load. This is usually prevented passively by limiting the penetration level of PV to very conservative values, even if the critical periods rarely occur. Alternatively, one can use active power curtailment (APC) techniques, reducing the amount of active power injected by the PV inverters, as the voltage at their buses increase above a certain value. In this way, it is possible to increase the installed PV capacity and energy yield while preventing overvoltage. This paper investigates a number of approaches for sizing and controlling the PV power generated by 12 net-zero energy houses equipped with large roof-top PV systems in a typical 240V/75kVA Canadian suburban radial distribution feeder. Simulations of a one year period with typical solar irradiance and load profiles are conducted with PSCAD to assess the performance of the different approaches in terms of overvoltage occurrence, sharing of the burden for overvoltage prevention per house and total energy yield of the residential PV feeder. Keywords-power distribution, overvoltages, solar power generation, power systems, power quality and voltage control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of solar photovoltaics on the low-voltage distribution network in New Zealand

Residential rooftop-mounted solar photovoltaic (PV) panels are being installed at an increasing rate, both in New Zealand and globally. There have been concerns over possible issues such as overvoltage and overcurrent. These PV systems are mostly connected at low voltage (LV). This study presents a case study of simulating the entire LV network from a single utility, comprising 10,558 11 kV–415...

متن کامل

Performance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT

The single-phase transformerless grid-connected photovoltaic (PV) systems, mainly the low-power single-phase systems, require high efficiency, small size, lightweight, and low-cost grid-connected inverters. However, problems such as leakage current, the DC current injection and safety issues are incorporated with transformerless grid-connected PV inverters. Besides, the new standards such as Lo...

متن کامل

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

Increasing Grid Transmission Capacity and Power Quality by a New Solar Inverter Concept in Low Voltage Grids with a High Proportion of Distributed Power Plants

The proportion of renewable energies in power generation has increased according to the political aims in recent years. In low-voltage grids, these are mostly decentralized renewable energy systems such as photovoltaic (PV) that are connected through inverters to the grid. The temporary reversal of the power flow causes overvoltage problems. Consequently, regenerative sources need to be turned ...

متن کامل

بررسی تاثیر کاهش محافظ‌کارانه ولتاژ بر برنامه‌ریزی بهره‌برداری بهینه شبکه‌ توزیع هوشمند در حضور خودروهای الکتریکی

To provide the required service quality to the consumers connected to the ending buses of radial distribution feeders, the voltage magnitude is set at higher values at the substation point and hence, at the buses located within the beginning feeder sections. The active and reactive powers are in touch with voltage magnitude at the corresponding buses. Accordingly, the voltage increase stimulate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012