Accoustic immitance measures in infants with 226 and 1000 hz probes: correlation with otoacoustic emissions and otoscopy examination.
نویسندگان
چکیده
UNLABELLED Audiological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. AIM To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. METHODS Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two groups of 30 infants each, according to the presence or absence of otoacoustic emissions (OAE). All babies have undergone tympanometry with probe tones of 226 and 1000 Hz and ENT evaluation. RESULTS Tests performed with 1000 Hz probe tone were more sensitive in identifying middle ear disorders. In children with normal tympanograms, both probe tones (226 and 1000 Hz) showed high specificity. All correlations were significant when the 1000 Hz probe tone was used. CONCLUSION The high frequency probe tone (1000 Hz) presented the most significant correlation with OAE and otoscopy in infants from zero to four months of age.
منابع مشابه
Accoustic immitance measures in infants with 226 and 1000 hz probes : correlation with otoacoustic emissions and otoscopy examination Summary
Audi ological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. Aim: To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. Methods: Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two groups of 3...
متن کاملTympanometry with 226 and 1000 Hertz tone probes in infants.
UNLABELLED This study aimed at describing and analyzing tympanometric results obtained with 226 Hz and 1000 Hz probe tones; checking for correlations between tympanometry, otoacoustic emissions and otoscopic examination; describing abnormal results found in the evaluation procedures. METHODS Double-blind and prospective study. Our sample included 70 babies, between 7 days and one month and 13...
متن کاملMultifrequency tympanometry in infants
INTRODUCTION The use of conventional tympanometry is not sufficiently sensitive to detect all cases of middle ear changes, and this hinders accurate diagnosis. OBJECTIVE To characterize acoustic immittance measures of infants from 0 to 3 months of age using multifrequency tympanometry in a prospective study. METHOD 54 infants from 0 to 3 months of age were evaluated. The inclusion criter...
متن کاملWideband reflectance in newborns with present transient-evoked otoacoustic emissions.
PURPOSE To characterize the normal values of acoustic energy reflectance obtained with pure-tone stimulation in neonates prior to hospital discharge. METHODS Seventy-seven infants (37 girls and 40 boys) were evaluated by measuring acoustic reflectance using pure-tone stimuli, transient-evoked otoacoustic emissions, and tympanometric probe frequencies of 226 Hz and 1 kHz. RESULTS At low freq...
متن کاملThe role of high frequency tympanometry in newborn hearing screening programme.
BACKGROUNDS AND OBJECTIVE The hearing assessment of the newborns ideally should detect both middle and inner ear functions. The aim of this study is to control the association between otoscopic evaluation, multifrequency tympanometry and TEOAE results. METHODS Fifty new-borns otherwise healthy were tested after the otolaryngological evaluation by 226 and 1000 Hz tympanometries and transient e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian journal of otorhinolaryngology
دوره 75 1 شماره
صفحات -
تاریخ انتشار 2009