Measuring tidal breathing parameters using a volumetric vest in neonates with and without lung disease.
نویسندگان
چکیده
Lung function measurement is difficult in unsedated infants; tidal breathing parameters are a useful non-invasive surrogate, but even these measurements cause disturbance from applying a facemask. We investigated a novel volumetric vest system (FloRight), which measures volume changes of the respiratory system from changes in the magnetic fields induced by current-carrying coils around the entire chest and abdomen. Using a facemask and ultrasonic flowmeter as comparator, we assessed the validity and repeatability of tidal breathing parameters measured by FloRight in 10 healthy newborn infants during natural sleep. We also assessed the effect of a facemask on tidal volume and tidal expiratory flow parameters. To assess the ability of the FloRight system to detect disease, we compared the healthy infants with 11 infants suffering from bronchopulmonary dysplasia. Tidal parameters with the FloRight vest corresponded closely with facemask measurements. Mean difference, mask minus vest, for tidal volume was 0.096 ml (P < 0.05), with limits of agreement +4.5 to -4.3 ml. Coefficient of repeatability was similar for mask and vest measurements. Tidal volume measured by FloRight with mask in place (20.6 ml) was significantly higher than without mask (16.1 ml), but tidal expiratory flow parameters were not altered. FloRight measurements of tidal parameters were markedly different between the two groups of infants, with tidal volume per Kg significantly higher and tidal expiratory flow parameters significantly lower. Our findings suggest that the FloRight system is able to measure tidal breathing parameters accurately, in healthy newborn infants, without prior calibration on the infant. It appears to have at least sufficient sensitivity to detect severe respiratory disease.
منابع مشابه
A Study of the Usability of Ergonomic Camera Vest Based on Spirometry Parameters
Background: Being a cameraman is one of those occupations that expose people to musculoskeletal disorders (MSDs). Therefore, control measures should be taken to protect cameramen’s health. To solve the given problem, a vest was designed for cameramen to prevent MSDs by reducing the pressure and contact stress while carrying the camera on their shoulder. However, the usability of vest had ...
متن کاملCharacterizing airway and alveolar nitric oxide exchange during tidal breathing using a three-compartment model.
Exhaled nitric oxide (NO) may be a useful marker of lung inflammation, but the concentration is highly dependent on exhalation flow rate due to a significant airway source. Current methods for partitioning pulmonary NO gas exchange into airway and alveolar regions utilize multiple exhalation flow rates or a single-breath maneuver with a preexpiratory breath hold, which is cumbersome for childre...
متن کاملElectromagnetic inductance plethysmography is well suited to measure tidal breathing in infants
Reliable, accurate and noninvasive methods for measuring lung function in infants are desirable. Electromagnetic inductance plethysmography has been used to perform infant spirometry and VoluSense Pediatrics (VSP) (VoluSense, Bergen, Norway) represents an updated version of this technique. We aimed to examine its accuracy compared to a validated system measuring airflow via a facemask using an ...
متن کاملLung function at term in extremely preterm-born infants: a regional prospective cohort study
OBJECTIVES To compare lung function of extremely preterm (EP)-born infants with and without bronchopulmonary dysplasia (BPD) with that of healthy term-born infants, and to determine which perinatal characteristics were associated with lung function at term and how predictive these measurements were for later respiratory health in EP-born infants. METHODS Perinatal variables were recorded pros...
متن کاملبررسی نیازهای توجهی کنترل الگوی تنفس و ارتباط آن با پیامدهای متابولیکی تنفس در افراد سالم
Objective: Normal breathing is essential for adjustment of natural metabolism of human body. Therefore, the aim of this study was to evaluate the control of breathing pattern in normal subjects both at rest and during cognitive loading. Materials & Methods: In this quasi-experimental study, 24 healthy subjects (14 males, 10 females) were selected by simple and convenient sampling. Spirometry...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pediatric pulmonology
دوره 45 11 شماره
صفحات -
تاریخ انتشار 2010