High-accuracy calculation of the blackbody radiation shift in the 133Cs primary frequency standard.

نویسندگان

  • K Beloy
  • U I Safronova
  • A Derevianko
چکیده

The blackbody radiation (BBR) shift is an important systematic correction for the atomic frequency standards realizing the SI unit of time. Presently, there is controversy over the value of the BBR shift for the primary 133Cs standard. At room temperatures, the values from various groups differ at the 3x10(-15) level, while modern clocks are aiming at 10(-16) accuracies. We carry out high-precision relativistic many-body calculations of the BBR shift. For the BBR coefficient beta at T=300 K, we obtain beta=-(1.710+/-0.006)x10(-14), implying 6x10(-17) fractional uncertainty. While in accord with the most accurate measurement, our 0.35% accurate value is in a substantial (10%) disagreement with recent semiempirical calculations. We identify an oversight in those calculations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-accuracy measurement of the blackbody radiation frequency shift of the ground-state hyperfine transition in 133Cs.

We report a high-accuracy direct measurement of the blackbody radiation shift of the 133Cs ground-state hyperfine transition. This frequency shift is one of the largest systematic frequency biases encountered in realizing the current definition of the International System of Units (SI) second. Uncertainty in the blackbody radiation frequency shift correction has led to its being the focus of in...

متن کامل

. at om - p h ] 1 7 O ct 2 00 3 Black Body Radiation Shift of the 133 Cs Hyperfine Transition Frequency

We report the theoretical evaluations of the static scalar polarizability of the 133Cs ground state and of the black body radiation shift induced on the transition frequency between the two hyperfine levels with mF = 0. This shift is of fundamental importance in the evaluation of the accuracy of the primary frequency standards based on atomic fountains and employed in the realization of the SI ...

متن کامل

An Approach in Radiation Therapy Treatment Planning: A Fast, GPU-Based Monte Carlo Method

Introduction: An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. Materials and Methods: A program was written for parallel runnin...

متن کامل

First accuracy evaluation of NIST-F2

We report the first accuracy evaluation of NIST-F2, a second-generation laser-cooled caesium fountain primary standard developed at the National Institute of Standards and Technology (NIST) with a cryogenic (liquid nitrogen) microwave cavity and flight region. The 80 K atom interrogation environment reduces the uncertainty due to the blackbody radiation shift by more than a factor of 50. Also, ...

متن کامل

Evaluation of CorePlanTM treatment planning system for 6 and 15 MV photon irradiation

Introduction: Radiotherapy is an effective modality to treat esophageal carcinoma. Due to various inhomogenous tissues with a variety of physical and radiological properties which can cause uncertainty in accurate dose calculations in radiation therapy, accuracy of TPS is very important. The aim of this study was to quantify dose calculation accuracy of CoreplanTM TPS in an inh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 97 4  شماره 

صفحات  -

تاریخ انتشار 2006