Outcome of 2 cc pure sulfur hexafluoride gas tamponade for macular hole surgery

نویسندگان

  • Naresh B. Kannan
  • Olukorede O. Adenuga
  • Karthik Kumar
  • Kim Ramasamy
چکیده

BACKGROUND Isoexpansile concentrations of intraocular gases are typically used as tamponading agent in macular hole surgery. Using a small volume of the pure form of these gases may achieve the same result without increasing the incidence of postoperative complications. The purpose of this study was to evaluate the anatomical and visual outcomes following macular hole surgery with 2 cc pure (100 %) sulfur hexafluoride (SF6) gas tamponade. METHODS A retrospective study of eyes with idiopathic macular holes that underwent 23-gauge pars plana vitrectomy with 2 cc pure SF6 gas tamponade. Macular hole surgery was performed alone or in combination with phacoemulsification in eyes with cataract. Preoperative and postoperative data including best corrected visual acuity recorded in LogMAR units, slit-lamp biomicroscopy, and optical coherence tomography were analysed. Surgical complications were also recorded. RESULTS Seventy six eyes of seventy five patients were analysed. A closure rate of 100 % was achieved with reoperation in 4 eyes. There was a significant improvement in best-corrected visual acuity from a mean of 0.65 LogMAR preoperatively to 0.36 at 6 months (p value 0.004). Forty five (59 %) eyes gained at least 2 lines on the Snellen visual acuity chart. Postoperative elevation in intraocular pressure (≥30 mmHg) was documented in 3 eyes (4 %). CONCLUSION Macular hole surgery with 2 cc pure SF6 gas tamponade achieved a high success rate with a low incidence of complications. The smaller volume of gas required makes it a cheaper technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcomes of sulfur hexafluoride (SF6) versus perfluoropropane (C3F8) gas tamponade for macular hole surgery.

PURPOSE To compare outcomes of macular hole surgery using sulfur hexafluoride (SF6) gas versus perfluoropropane (C3F8) gas for idiopathic macular hole repair. DESIGN Retrospective, interventional, comparative cohort study. METHODS Institutional clinical practice. A consecutive group of patients undergoing macular hole surgery with SF6 group (38 eyes of 38 patients) and a nonconsecutive, con...

متن کامل

Macular hole surgery under retrobulbar local anesthesia increases visual acuity

METHODS A retrospective study on medical records of patients who had undergone macular hole surgery under local anesthesia. Funduscopic examination of macular hole had been performed and all other diseases with deterioration of visual acuity eliminated. Surgery was performed under retrobulbar local anesthesia, using 2 ml of 2% lidocaine mixed with 3 ml bupivacaine in one syringe. Vitreous tampo...

متن کامل

Sulfur hexafluoride (SF6) versus perfluoropropane (C3F8) tamponade and short term face-down position for macular hole repair: a randomized prospective study

BACKGROUND To compare early visual and anatomical outcomes after either sulfur hexafluoride (SF6) or perfluoropropane (C3F8) tamponade for macular hole repair. METHODS 147 eyes affected by primary full-thickness macular hole underwent pars plana vitrectomy with dye assisted removal of the internal limiting membrane and gas tamponade. Prone position was prescribed for 48 h after surgery. All p...

متن کامل

Macular hole surgery with short-acting gas and short-duration face-down positioning

PURPOSE To report on the outcomes of vitrectomy and sulfur hexafluoride (SF(6)) gas tamponade for idiopathic macular holes with 2 days of face-down positioning. PATIENTS AND METHODS This was a prospective, nonrandomized, observational sequential case-series study on 23 consecutive patients receiving macular hole surgery using 20% SF(6) and advised to stay in a face-down position for 2 days po...

متن کامل

Wide-field laser ophthalmoscopy for imaging of gas-filled eyes after macular hole surgery

BACKGROUND AND OBJECTIVE Existing ophthalmoscopy methods are unable to obtain clear fundus autofluorescence (FAF) images in gas-filled eyes. The purpose of this study was to evaluate the capability of wide-field laser ophthalmoscopy (Optos) in obtaining FAF images in gas-filled eyes for the assessment of macular hole (MH) closure after surgery. METHODS This was an interventional case series. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016