Applications of the normal-incidence rotating-sample ellipsometer to high- and low-spatial-frequency gratings.
نویسندگان
چکیده
The normal-incidence rotating-sample ellipsometer is an instrument that can be used to characterize grating surfaces from the measured ratio ρof complex reflection coefficients r(y)/r(x) of light polarized perpendicular and parallel to the grating groove direction. Experimental results at different wavelengths for different gratings with spatial frequencies from 150 to 5880 grooves/mm are presented. The groove depth of the 5880-grooves/mm gold-coated grating can be estimated from the measured ρ and rigorous grating theory.
منابع مشابه
Synchrotron radiation-based far-infrared spectroscopic ellipsometer with full Mueller-matrix capability.
We developed far-IR spectroscopic ellipsometer at the U4IR beamline of the National Synchrotron Light Source in Brookhaven National Laboratory. This ellipsometer is able to measure both, rotating analyzer and full-Mueller matrix spectra using rotating retarders, and wire-grid linear polarizers. We utilize exceptional brightness of synchrotron radiation in the broad spectral range between about ...
متن کاملCombined Spatial Filter and Relay Systems in Rotating Compensator Ellipsometer/Polimeter
Liphardt et al. (*) Notice: Subject to any disclaimer, the term of this patent is extended or adjusted under 35 U.S.C. 154(b) by 0 days. This patent is subject to a terminal dis-claimer. ABSTRACT Low aberration relay systems modified to perform as spatial filters in rotating compensator ellipsometer, polarimeter and the like systems.
متن کاملThe Applications of the Heterodyne Interferoemetry
Optical interferometry is widely used in many precision measurements such as displacement[1, 2], vibration[3, 4], surface roughness[5, 6], and optical properties[7-14] of the object. For example, holographic interferomter [1-3] can be used to measure the surface topography of the rigid object. The emulsion side of the photographic plate faces the object and is illuminated by a plane wave at nor...
متن کاملGeographic Information System of Stroke Incidence in Zanjan Province, Iran During 2012-2019
Background and Objective: Stroke is the second leading cause of mortality and the third leading cause of morbidity worldwide. This study aimed to examine the spatial-temporal distribution of stroke in rural districts, Zanjan Province, Iran. Materials and Methods: This cross-sectional study was conducted at Zanjan University of Medical Sciences (ZUMS). Patients with a discharge diagnosis of str...
متن کاملRotating analyzer–fixed analyzer ellipsometer based on null type ellipsometer
The theory and design of an inexpensive rotating analyzer unit is presented, which allows a conventional null type ellipsometer to work as rotating analyzer–fixed analyzer automatic ellipsometer, without sacrificing the possibility to work in null mode. The mode switching is performed simply by adding or removing the rotating analyzer from its holder. It is shown that the rotating analyzer phas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 35 13 شماره
صفحات -