The effects of arm elevation on the 3-dimensional acromiohumeral distance: a biplane fluoroscopy study with normative data.
نویسندگان
چکیده
HYPOTHESIS AND BACKGROUND Narrowing of the subacromial space has been implicated in several shoulder pathologies. However, the location of the minimum distance points during clinical testing has not been defined. We sought to measure the in vivo minimum distance and location of the minimum distance points on the acromion and proximal humerus during arm elevation. METHODS Eight healthy male subjects (mean age, 30 years) underwent a dynamic in vivo biplane fluoroscopy assessment of scaption and forward elevation. For each frame, the 3-dimensional position and orientation of the humerus and scapula were determined, and the acromiohumeral distance (AHD) was measured as the shortest distance between the acromion and proximal humerus. RESULTS The minimum AHD was 2.6 ± 0.8 mm during scaption and 1.8 ± 1.2 mm during forward flexion at elevation angles of 83° ± 13° and 97° ± 23°, respectively. The minimum distance point was located on the articular surface of the humeral head from the neutral arm position until 34° ± 8° for scaption and 36° ± 6° for forward flexion. Upon further elevation, the minimum distance point was located within the footprint of the supraspinatus muscle until 72° ± 12° for scaption and 65° ± 8° for forward flexion. At greater elevation angles, the minimum distance points were between the acromion and the proximal humeral shaft, distal from the greater tuberosity. CONCLUSIONS The shortest AHD was at approximately 90° of arm elevation. The AHD was no longer measured intra-articularly or within the supraspinatus footprint above approximately 70° of arm elevation.
منابع مشابه
The comparison of acromiohumeral distance and scapular dyskinesis prevalence in females with and without rounded shoulder posture
Background: Altered scapular kinematics in individuals with rounded shoulder posture (RSP) may affect acromiohumeral distance (AHD). The purpose of this study was to compare AHD and scapular dyskinesis prevalence in individuals with and without RSP. Methods: A total of 44 women (RSP, n=21; control, n=23) participated in the study. RSP was assessed by measuring acromion to table distance (AT...
متن کاملEffect of plane of arm elevation on glenohumeral kinematics: a normative biplane fluoroscopy study.
BACKGROUND Understanding glenohumeral motion in normal and pathologic states requires the precise measurement of shoulder kinematics. The effect of the plane of arm elevation on glenohumeral translations and rotations remains largely unknown. The purpose of this study was to measure the three-dimensional glenohumeral translations and rotations during arm elevation in healthy subjects. METHODS...
متن کاملCoracohumeral Distances and Correlation to Arm Rotation: An In Vivo 3-Dimensional Biplane Fluoroscopy Study.
BACKGROUND Reduced coracohumeral distances have been reported to be associated with anterior shoulder disorders such as subscapularis tears, biceps tendon injuries, and leading edge supraspinatus tears. PURPOSE To determine the variability in coracohumeral distance as a function of arm rotation in healthy male subjects. The null hypothesis was that no differences in coracohumeral distance wou...
متن کاملAssessment of subacromial space and its relationship with scapular upward rotation in college baseball players.
CONTEXT Subacromial impingement is a common injury in baseball players and has been linked to a reduction in the subacromial space. In addition, it has been suggested that decreases in scapular upward rotation will lead to decreases in the subacromial space and ultimately impingement syndrome. OBJECTIVE The objective of this study was to evaluate the relationship between acromiohumeral distan...
متن کامل3-D Respiratory Motion Compensation during EP Procedures by Image-Based 3-D Lasso Catheter Model Generation and Tracking
Radio-frequency catheter ablation of the pulmonary veins attached to the left atrium is usually carried out under fluoroscopy guidance. Two-dimensional X-ray navigation may involve overlay images derived from a static pre-operative 3-D volumetric data set to add anatomical details. However, respiratory motion may impair the utility of static overlay images for catheter navigation. We developed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of shoulder and elbow surgery
دوره 21 11 شماره
صفحات -
تاریخ انتشار 2012