Continuous in vivo blood pressure measurements using a fully implantable wireless SAW sensor
نویسندگان
چکیده
In this paper, the development of a fully implantable wireless sensor able to provide continuous real-time accurate pressure measurements is presented. Surface Acoustic Wave (SAW) technology was used to deposit resonators on crystalline quartz wafers; the wafers were then assembled to produce a pressure sensitive device. Excitation and reading via a miniature antenna attached to the pressure sensor enables continuous external interrogation. The main advantages of such a configuration are the long term stability of quartz and the low power necessary for the interrogation, which allows 24/7 interrogation by means of a hand-held, battery powered device. Such data are of vital importance to clinicians monitoring and treating the effects of hypertension and heart failure. A prototype was designed and tested using both a bio-phantom test rig and an animal model. The pressure traces for both compare very well with a commercially available catheter tip pressure transducer. The work presented in this paper is the first known wireless pressure data from the left ventricle of the heart of a living swine.
منابع مشابه
کاربردهای شبکههای حسگر بدنی در حوزه ی سلامت: مروری بر منابع
Background and Aim: Nowadays, one of the most important areas of application of information technology in the health sector is monitoring patients' condition. Recently utilization of body area sensor networks in healthcare had significant advances. The purpose of this article is to examine the applications of wireless health sensor networks in the field of health. Materials and Methods: This ...
متن کاملA self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats.
Using Bluetooth wireless technology, we developed an implantable telemetry system for measurement of the left ventricular pressure-volume relation in conscious, freely moving rats. The telemetry system consisted of a pressure-conductance catheter (1.8-Fr) connected to a small (14-g) fully implantable signal transmitter. To make the system fully telemetric, calibrations such as blood resistivity...
متن کاملLeft Atrial Pressure Monitoring With an Implantable Wireless Pressure Sensor After Implantation of a Left Ventricular Assist Device
After implantation of a continuous-flow left ventricular assist device (LVAD), left atrial pressure (LAP) monitoring allows for the precise management of intravascular volume, inotropic therapy, and pump speed. In this case series of 4 LVAD recipients, we report the first clinical use of this wireless pressure sensor for the long-term monitoring of LAP during LVAD support. A wireless microelect...
متن کاملAn implantable ZigBee ready telemetric platform for in vivo monitoring of physiological parameters
This paper presents a multiple channel, bidirectional and implantable biotelemetric platform, suitable for real time in vivo monitoring of several physiological parameters. This system consists of an implantable unit, an external host and a user terminal. The ZigBee wireless technology, functioning as telemetric link, enables long battery lifetime and offers the opportunity to build up complex ...
متن کاملDesign, Fabrication, and Implementation of a Wireless, Passive Implantable Pressure Sensor Based on Magnetic Higher-Order Harmonic Fields
A passive and wireless sensor was developed for monitoring pressure in vivo. Structurally, the pressure sensor, referred to as the magneto-harmonic pressure sensor, is an airtight chamber sealed with an elastic pressure membrane. A strip of magnetically-soft material is attached to the bottom of the chamber and a permanent magnet strip is embedded inside the membrane. Under the excitation of an...
متن کامل