09:00 09:25 Coffee and registration 09:25 09:30 Introduction 09:30 10:00 Quantification of the Renogram: Deconvolution and Patlak/Rutland Plot Prof Richard Lawson, Central Manchester Nuclear Medicine Centre, Manchester 10:00 10:30 Improving quantification via multi-modality imaging Prof Brian Hutton, University College London 10:30 11:00 Coffee, Posters and Exhibiton 11:00 11:20 Use of the CT Scout View (Topogram) for Accurate Attenuation Correction of Planar Quantitative Studies Gregory James, City Hospital, Birmingham 11:20 11:40 Optimised cardiac MUGA scanning via quantitative methods Shelley Redgate, Sheffield Teaching Hospitals Foundation NHS Trust, Sheffield 11:40 12:00 Quantitation in GFRs – can less really be more? Maria Burniston, Royal Free London NHS Foundation Trust, London 12:00 12:10 Questions 12:10 13:10 Lunch, Posters and Exhibiton 13:10 13:30 Tc-DPD SPECT quantitation for patients with transthyretin cardiac amyloidosis James Ross, Royal Free London NHS Foundation Trust, London 13:30 13:50 Image based Monte Carlo simulation of Peptide Receptor Radionuclide Therapy Salvatore Berenato, Cardiff University, Cardiff 13:50 14:10 Improving consistency in blood-pool SUV quantification specifically in F-FDG studies of Cardiac Sarcoidosis James Hubber, Imperial College Healthcare Trust, London 14:10 14:30 Improving SUV normalisation for 18F-FDG PET/CT using CT fat segmentation Glenn Woolley, Royal Free London NHS Foundation Trust, London 14:30 14:40 Questions 14:40 15:00 Coffee, Posters and Exhibiton 15:00 15:20 Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT Ian Armstrong, Central Manchester University Hospitals, Manchester 15:20 15:40 Reproducible quantification in Tc-99m SPECT/CT Laura Cluny, NHS Lothian 15:40 16:00 Novel SPECT Reconstruction for 123I-DaTSCAN Studies Aids Visual Assessment Colin Brown, Gartnavel General Hospital, Glasgow 16:00 16:15 Questions/discussion 16:15 Close

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative evaluation of normal uptake of mandibular condyle in bone scan with Tc 99m-MDP [Persian]

Unilateral condylar hyperplasia is the main cause of mandibular asymmetry. Radionuclide bone scanning is a useful procedure for functional evaluation of temporomandibular joint. In this study, 39 patients with normal bone scan and no facial asymmetry were studied. All patients were below 22 years of age. Normal condylar uptake was determined in this group of patients. Right & left condyla...

متن کامل

Improved quantification of salivary gland scintigraphy by means of factor analysis

Introduction: In this study the automatic separation of oral and salivary gland activity and spontaneous secretion by means of factor analysis for quantitative salivary gland scintigraphy is introduced. Methods: After intravenous administration of 99mTc sodium pertechnetate, dynamic scintigraphy was performed. 20 minutes after tracer application 2 ml of lemon juice was delivered to stimulate t...

متن کامل

Evaluating the Effect of Injected Dose of 99mTc- MIBI on the Quantitative Parameters of Myocardial Perfusion Imaging

Background: 99mTc-MIBI cardiac perfusion scanning is recognized as a clinically useful method in evaluating coronary artery disease. By the implementation of new imaging techniques and systems, it seems possible to obtain high-quality images with a lower dose of radiopharmaceuticals. The purpose of this study was to evaluate the effect of injection dose of 99mTc-MIBI on quantitative parameters ...

متن کامل

Two-day stress-rest lower limbs perfusion scan in patients referred for myocardial perfusion imaging

Introduction: Peripheral Vascular Disease (PVD) is a major cause of morbidity and is associated with Coronary Artery Disease (CAD). We aimed to perform Lower Limb Perfusion Scan (LLPS) in patients referred for Myocardial Perfusion Imaging (MPI) and estimate prevalence of PVD in subgroups with normal and abnormal MPI results. We also compared quantitative indices of LLPS in pati...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Quantitative Assessment of Conventional and Modern De-Noising on Nuclear Medicine Images

Introduction: One of the major problems in the development of nuclear medicine images is the presence of noise. The noise level in nuclear medicine images is usually reduced by the analysis of imaging data in a Fourier transform environment. The main drawback of this environment belongs to low signal to noise ratio in high frequencies because removing noise frequencies may remove data and times...