In vivo uptake and elimination of isoflurane by different membrane oxygenators during cardiopulmonary bypass.
نویسندگان
چکیده
BACKGROUND Volatile anesthetics are frequently used during cardiopulmonary bypass (CPB) to maintain anesthesia. Uptake and elimination of the volatile agent are dependent on the composition of the oxygenator. This study was designed to evaluate whether the in vivo uptake and elimination of isoflurane differs between microporous membrane oxygenators containing a conventional polypropylene (PPL) membrane and oxygenators with a new poly-(4-methyl-1-pentene) (PMP) membrane measuring isoflurane concentrations in blood. METHODS Twenty-four patients undergoing elective coronary bypass surgery with the aid of CPB were randomly allocated to one of four groups, using either one of two different PPL-membrane oxygenators for CPB or one of two different PMP-membrane oxygenators. During hypothermic CPB, 1% isoflurane in an oxygen-air mixture was added to the oxygenator gas inflow line (gas flow, 3 l/min) for 15 min. Isoflurane concentration was measured in blood and in exhaust gas at the outflow port of the oxygenator. Between-group comparisons were performed for the area under the curve (AUC) during uptake and elimination of the isoflurane blood concentrations, the maximum isoflurane blood concentration (C(max)), and the exhausted isoflurane concentration (F(E)). RESULTS The uptake of isoflurane, expressed as AUC of isoflurane blood concentration and a function of F(E), was significantly reduced in PMP oxygenators compared to PPL oxygenators (P < 0.01). C(max) was between 8.5 and 13 times lower in the PMP-membrane oxygenator groups compared to the conventional PPL-membrane oxygenator groups (P < 0.01). CONCLUSIONS The uptake of isoflurane into blood via PMP oxygenators during CPB is severely limited. This should be taken into consideration in cases using such devices.
منابع مشابه
Depth of Anaesthesia Associated with 2.5% Isoflurane During Cardiopulmonary Bypass
Background/Introduction Since its inception, and to this day, measurement of the depth anaesthesia during cardiopulmonary bypass (CPB) has been challenging. Bispectral index (BIS) is commonly used but remains controversial. One pragmatic approach to anaesthesia is to administer 2.5% isoflurane into the sweep gas supply to the oxygenator and allow neuromuscular blockade to fade so that patient m...
متن کاملGaseous microemboli and the influence of microporous membrane oxygenators.
Gaseous microemboli (GME) are still an unsolved problem of extracorporeal circuits. They are associated with organ injury during cardiopulmonary bypass. Microbubbles of different sizes and number are generated in the blood as the result of different components of the extracorporeal circuit as well as surgical maneuvers. The aim of our study was to observe the behavior of microporous membrane ox...
متن کاملAn in vitro protocol for evaluation and comparison of membrane oxygenators.
With the trend in open heart surgery toward normothermic bypass and warm blood cardioplegia, greater demand is being placed on the perfusionist to select an oxygenator that will perform safely and efficiently under a variety of conditions. While manufacturers report performance parameters for their products, the data is often not comparable due to widely differing conditions. Recent in vitro ...
متن کاملThe Physical Effects Of Volatile Anesthetics On Polycarbonate Membrane Oxygenators
The spillage of enflurane on the outside of a membrane oxygenator during cardiopulmonary bypass resulted in a leak at the venous outlet, with nearly fatal outcome. We studied the effect of three different volatile anesthetics on the polycarbonate parts of unused and used COBE CMS membrane oxygenators with 30-HRV open filtered reservoir. The polycarbonate parts were submitted to a series of test...
متن کاملExtraction of Nitroglycerin by a Membrane Oxygenator
This study examined the extraction efficiency of a membrane oxygenator for nitroglycerin (NTG). An In-Vitro cardiopulmonary bypass circuit was constructed to mimic clinical conditions. A NTG solution (150 ng/ml) was placed into the circuit via a glass cardiotomy reservoir and circulated at 5 Ll min for 60 min. Analysis of NTG samples obtained during the study showed that the oxygenator initiall...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 97 1 شماره
صفحات -
تاریخ انتشار 2002