Catalytic Spectrophotometric Determination of Chromium
نویسندگان
چکیده
chromium(III) up to 100 ng mL−1, and for chromium(VI) up to 200 ng mL−1) were obtained, using the “fixed time” method with detection limits of 4.9 ng mL−1 and 3.8 ng mL−1, respectively. The results suggest that at the reaction conditions chromium(VI) is reduced and chromium(III) is oxidized to an intermediate oxidation state and the catalytic action of chromium is due to the formation of an active complex between oxidant, catalyst and substrate. A new catalytic spectrophotometric method for the determination of chromium was developed. The proposed method was successfully applied to chromium determination in tap and industrial waters.
منابع مشابه
Determination of ultra trace amount Chromium in water samples with the 1-(2-PyridylAzo)-2-Naphthol, (PAN) by the bromate ion in sulfuric acid with kinetic spectrophotometric method
A new kinetic spectrophotometic method for the determination of trace amount Chromium (III) in Teareal samples has been described based on it s the catalytic effect on the oxidations of 1 - ( 2 –PyridylAzo ) - 2 - Naphthol, (PAN), by potassium bromated in sulfuric acid. The reaction is followedspec- trophotometrically by measuring the decrease in the absorbance at 469 nm. Under the optimumcondi...
متن کاملCatalytic-Spectrophotometric Determination of Trace Amounts of Manganese(II) by Catalysis of the Oxidation of Ferroin with Periodate
A catalytic spectrophotometric method for determination of ultra-trace quantities of manganese(II) id described. The method is based on the catalytic effect of manganese(II) on the oxidation reaction of ferroin by potassium periodate in acidic media. The reaction is monitored spectrophotometrically at 510 nm by a slope method and Mn(II) is determinable in the range of 1-1000ngmL-1</sup...
متن کاملSPECTROPHOTOMETRIC REACTION RATE METHOD FOR THE DETERMINATION OF SLWR BASED ON ITS CATALYTIC EFFEICT ON THE OXIDATION OF GLLOCYANW BY PER0XYDISULPTE
A sensitive and selective procedure was developed for the spectrophotometric determination of silver by its catalytic effect on the oxidation of gallocyanine by peroxydisulphate in acidic media at 540 nm. Silver can be determined in the range of 0.001-0.500 µg/ml with a limit of detection of 0.0005 µg/ml, by a fixed-time method of 4.0 min from initiation of the reaction, The relative standa...
متن کاملCatalytic Spectrophotometric Determination of Traces of Tellurium (IV)
A Simple, rapid and sensitive method has been developed for determination of trances of tellurium (VI) (0.096-1.250 mg/mL) based on its catalytic effect on the reduction reaction of toluidine blue by sulfide ion at pH 4. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 628 nm by the fixed time method. The detection...
متن کاملSPECTROPHOTOMETRIC REACTION RATE METHOD FOR THE DETERMINATION OF NITRITE BY CATALYTIC ACTION ON NILE BLUE A BROMATE REACTION
A kinetic method developed for the determination of ultra-trace amounts of nitrite based on its catalytic effect on the reaction between potassium bromate and Nile blue A in strongly acidic media is reported. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of Nile blue A at 645 nm by the fixed-time method. The decrease in absorbance during the first...
متن کامل