Optimisation of the environmental scanning electron microscope for observation of drying of matt water-based lacquers.
نویسندگان
چکیده
Environmental scanning electron microscopy (ESEM) modifies conventional SEM through the use of a partial gas pressure in the microscope specimen chamber. Like conventional SEM, it has the resolution to image structure on the submicron lengthscale, but can also tolerate hydrated specimens if water vapour is used in the specimen chamber. This ability to image aqueous specimens leaves ESEM uniquely placed to study in situ drying in polymer latexes. However, there are two key practical difficulties associated with in situ drying. First, the size of the latex particles: larger latex particles are typically around 500 nm in diameter. Although ESEM can resolve structure on this lengthscale without difficulty, the magnification required results in radiation damage of the specimen due to the electron beam. This means that a given region can be imaged only once during film formation, so the evolution of particular features cannot be followed. Second, the change from ambient temperature and pressure to the ESEM conditions of 7 degrees C and 7.5 torr (100 Pa) can subject the specimen to a very high evaporation rate, which can disrupt film formation. The inclusion of a drop of water in the specimen chamber is shown largely to alleviate this, enabling successful imaging of film formation in the lacquer. Instead of the polymer latex itself, this work concentrates on a matting lacquer with silica inclusions. The silica matting agent particles are 1-10 microm in size, allowing for a lower magnification to be used, massively reducing specimen damage. Furthermore, the contrast during drying is much enhanced in the presence of silica. The images reveal the silica as bright regions against a darker background of polymer and water. Film formation shows the transition from a uniform, featureless aqueous solution to a polymer film with silica particles present on the surface. The appearance of individual silica particles can be followed. The particles are generally revealed quite early, after a few minutes of drying time. As film formation progresses, these same particles appear larger and more distinct. Few new particles are revealed at longer film formation times.
منابع مشابه
Fractographic Studies of Plastic-embedded Cells by Scanning Electron Microscopy
Three-dimensional views of cell structures at high magnifications made possible by the scanning electron microscope (SEM) are becoming increasingly useful to biologists. Methods that have proved useful for stabilizing biological soft tissue for observation in the SEM include the critical point method (1, 2), freeze drying, freeze fracturing followed by freeze drying (4, 9, 10), observation of s...
متن کاملAdvantages of environmental scanning electron microscopy in studies of microorganisms.
Microorganisms, including bacteria, fungi, protozoa, and microalgae, are composed predominantly of water which prohibits direct observation in a traditional scanning electron microscope (SEM). Preparation for SEM requires that microorganisms be fixed, frozen or dehydrated, and coated with a conductive film before observation in a high vacuum environment. Sample preparation may mechanically dist...
متن کاملApplication of Environmental Scanning Electron Microscope-Nanomanipulation System on Spheroplast Yeast Cells Surface Observation
The preparation and observations of spheroplast W303 cells are described with Environmental Scanning Electron Microscope (ESEM). The spheroplasting conversion was successfully confirmed qualitatively, by the evaluation of the morphological change between the normal W303 cells and the spheroplast W303 cells, and quantitatively, by determining the spheroplast conversion percentage based on the OD...
متن کاملEffects of Spray Drying and Spray Chilling on Ibuprofen Dissolution
The formulation of hydrophobic drugs for oral drug delivery is challenging due to poor solubility, poor dissolution and poor wetting of these drugs. Consequently, the aim of this study was to improve the dissolution of a model poorly water soluble drug, ibuprofen. Microparticles containing ibuprofen were produced by spray drying and spray chilling technology in the absence/presence of a ...
متن کاملThe Effect of Lyophilization on Light Transmission of Amniotic Membrane: A Comparison with Rabbit Cornea
Background & Aims: Amniotic membrane persists for a long time after ocular transplantation (as corneal substitute) and can affect light transmission (transparency). The aim of this study was to evaluate the transparency of amniotic membrane after freeze-drying (lyophilization) and to compare the results with transparency of rabbit cornea. Methods: Transparency of rabbits’ corneas and fresh and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Scanning
دوره 24 6 شماره
صفحات -
تاریخ انتشار 2002