Rapid multi-orientation quantitative susceptibility mapping
نویسندگان
چکیده
Three-dimensional gradient echo (GRE) is the main workhorse sequence used for susceptibility weighted imaging (SWI), quantitative susceptibility mapping (QSM), and susceptibility tensor imaging (STI). Achieving optimal phase signal-to-noise ratio requires late echo times, thus necessitating a long repetition time (TR). Combined with the large encoding burden of whole-brain coverage with high resolution, this leads to increased scan time. Further, the dipole kernel relating the tissue phase to the underlying susceptibility distribution undersamples the frequency content of the susceptibility map. Scans at multiple head orientations along with calculation of susceptibility through multi-orientation sampling (COSMOS) are one way to effectively mitigate this issue. Additionally, STI requires a minimum of 6 head orientations to solve for the independent tensor elements in each voxel. The requirements of high-resolution imaging with long TR at multiple orientations substantially lengthen the acquisition of COSMOS and STI. The goal of this work is to dramatically speed up susceptibility mapping at multiple head orientations. We demonstrate highly efficient acquisition using 3D-GRE with Wave-CAIPI and dramatically reduce the acquisition time of these protocols. Using R=15-fold acceleration with Wave-CAIPI permits acquisition per head orientation in 90s at 1.1mm isotropic resolution, and 5:35min at 0.5mm isotropic resolution. Since Wave-CAIPI fully harnesses the 3D spatial encoding capability of receive arrays, the maximum g-factor noise amplification remains below 1.30 at 3T and 1.12 at 7T. This allows a 30-min exam for STI with 12 orientations, thus paving the way to its clinical application.
منابع مشابه
Rapid Acquisition for Multi-Orientation QSM
INTRODUCTION: Quantitative Susceptibility Mapping (QSM) involves the solution of the system DFχ = Fφ that relates the susceptibility map χ to the tissue phase φ derived from a gradient echo (GRE) experiment. In this relation, F is the 3D DFT operator, and D = 1/3 − k!/k is the kernel that undersamples the frequency content of χ on the surface 3k! = k!. The solution of this ill-conditioned syste...
متن کاملComparison of Two Quantitative Susceptibility Mapping Measurement Methods Used For Anatomical Localization of the Iron-Incorporated Deep Brain Nuclei
Introduction Quantitative susceptibility mapping (QSM) is a new contrast mechanism in magnetic resonance imaging (MRI). The images produced by the QSM enable researchers and clinicians to easily localize specific structures of the brain, such as deep brain nuclei. These nuclei are targets in many clinical applications and therefore their easy localization is a must. In this study, we aimed to i...
متن کاملRapid Multi-Orientation Susceptibility Mapping with Wave-CAIPI
Target Audience: Physicians and scientists interested in rapid Quantitative Susceptibility Mapping (QSM) and Susceptibility Tensor Imaging (STI). Purpose: QSM estimates the magnetic susceptibility that is related to subtle changes in the magnetic field through the dipole convolution , where and represent discrete Fourier transform and the dipole kernel. Inversion of this ill-posed system can be...
متن کاملHuman brain atlas for automated region of interest selection in quantitative susceptibility mapping: Application to determine iron content in deep gray matter structures
The purpose of this paper is to extend the single-subject Eve atlas from Johns Hopkins University, which currently contains diffusion tensor and T1-weighted anatomical maps, by including contrast based on quantitative susceptibility mapping. The new atlas combines a "deep gray matter parcellation map" (DGMPM) derived from a single-subject quantitative susceptibility map with the previously esta...
متن کاملSparse Methods for Quantitative Susceptibility Mapping
Quantitative Susceptibility Mapping (QSM) aims to estimate the tissue susceptibility distribution that gives rise to subtle changes in the main magnetic field, which are captured by the image phase in a gradient echo (GRE) experiment. The underlying susceptibility distribution is related to the acquired tissue phase through an ill-posed linear system. To facilitate its inversion, spatial regula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 125 شماره
صفحات -
تاریخ انتشار 2016