Novel therapeutic strategy against central baroreflex failure: a bionic baroreflex system.

نویسندگان

  • T Sato
  • T Kawada
  • T Shishido
  • M Sugimachi
  • J Alexander
  • K Sunagawa
چکیده

BACKGROUND Central baroreflex failure in Shy-Drager syndrome and traumatic spinal cord injuries results in severe orthostatic hypotension and often confines the patient to the bed. We proposed a novel therapeutic strategy against central baroreflex failure: implementation of an artificial feedback control system able automatically to regulate sympathetic vasomotor tone, that is, a bionic baroreflex system (BBS). With the use of a rat model of central baroreflex failure, we developed the BBS and tested its efficacy. METHODS AND RESULTS Our prototype BBS for the rat consisted of a pressure sensor placed into the aortic arch, stimulation electrodes implanted into the greater splanchnic nerve, and a computer-driven neural stimulator. By a white noise approach for system identification, we first estimated the dynamic properties underlying the normal baroreflex control of systemic arterial pressure (SAP) and then determined how the BBS computer should operate in real time as the artificial vasomotor center to mimic the dynamic properties of the native baroreflex. The open-loop transfer function of the artificial vasomotor center was identified as a high-pass filter with a corner frequency of 0.1 Hz. We evaluated the performance of the BBS in response to rapid-progressive hypotension secondary to sudden sympathetic withdrawal evoked by the local imposition of a pressure step on carotid sinus baroreceptors in 16 anesthetized rats. Without the BBS, SAP rapidly fell by 49+/-8 mm Hg in 10 seconds. With the BBS placed on-line with real-time execution, the SAP fall was suppressed by 22+/-6 mm Hg at the nadir and by 16+/-5 mm Hg at the plateau. These effects were statistically indistinguishable from those of the native baroreflex system. CONCLUSIONS These results suggest the feasibility of a BBS approach for central baroreflex failure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bionic technology revitalizes native baroreflex function in rats with baroreflex failure.

BACKGROUND We developed a bionic technology for the treatment of baroreflex failure and tested its efficacy in restoration of arterial pressure against head-up tilt (HUT) in rats with baroreflex failure. METHODS AND RESULTS The bionic baroreflex system (BBS) was a negative feedback system controlled by a computer, the artificial vasomotor center. It sensed systemic arterial pressure (SAP) thr...

متن کامل

Bionic epidural stimulation restores arterial pressure regulation during orthostasis.

A bionic baroreflex system (BBS) is a computer-assisted intelligent feedback system to control arterial pressure (AP) for the treatment of baroreflex failure. To apply this system clinically, an appropriate efferent neural (sympathetic vasomotor) interface has to be explored. We examined whether the spinal cord is a candidate site for such interface. In six anesthetized and baroreflex-deafferen...

متن کامل

Disruption of Central Antioxidant Property of Nuclear Factor Erythroid 2-Related Factor 2 Worsens Circulatory Homeostasis with Baroreflex Dysfunction in Heart Failure

Heart failure is defined as a disruption of circulatory homeostasis. We have demonstrated that baroreflex dysfunction strikingly disrupts circulatory homeostasis. Moreover, previous many reports have suggested that central excess oxidative stress causes sympathoexcitation in heart failure. However, the central mechanisms of baroreflex dysfunction with oxidative stress has not been fully clarifi...

متن کامل

تحریک الکتریکی هسته دسته منزوی ، حساسیت بارورفلکس را در رت های معتاد به مورفین افزایش می دهد

The previous studies have shown that the endogenous opiate system depress the baroreflex sensitivity in morphine dependent persons. Nucleus Tractus Soloitarii(NTS) is the main termination site of baroreceptor afferent neurons. The aim of this study was to determine the role of electrical stimulation of Nucleus Tractus    Soloitarii on baroreflex sensitivity in morphine...

متن کامل

Four faces of baroreflex failure: hypertensive crisis, volatile hypertension, orthostatic tachycardia, and malignant vagotonia.

BACKGROUND The baroreflex normally serves to buffer blood pressure against excessive rise or fall. Baroreflex failure occurs when afferent baroreceptive nerves or their central connections become impaired. In baroreflex failure, there is loss of buffering ability, and wide excursions of pressure and heart rate occur. Such excursions may derive from endogenous factors such as stress or drowsines...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 100 3  شماره 

صفحات  -

تاریخ انتشار 1999