Discriminating Hepatocellular Carcinoma in Rats Using a High-Tc SQUID Detected Nuclear Resonance Spectrometer in a Magnetic Shielding Box

نویسندگان

  • Kai-Wen Huang
  • Hsin-Hsien Chen
  • Hong-Chang Yang
  • Herng-Er Horng
  • Shu-Hsien Liao
  • Shieh Yueh Yang
  • Jen-Jie Chieh
  • Li-Ming Wang
چکیده

In this study, we report the spin-lattice relaxation rate of hepatocellular carcinoma (HCC) and normal liver tissue in rats using a high-T(c) superconducting quantum interference device (SQUID) based nuclear magnetic resonance (NMR) spectrometer. The resonance spectrometer used for discriminating liver tumors in rats via the difference in longitudinal relaxation time in low magnetic fields was set up in a compact and portable magnetic shielding box. The frequency-domain NMR signals of HCC tissues and normal liver tissues were analyzed to study their respective longitudinal relaxation rate T(1) (-1). The T(1) (-1) of liver tissues for ten normal rats and ten cancerous rats were investigated respectively. The averaged T(1) (-1) value of normal liver tissue was (6.41±0.66) s(-1), and the averaged T(1) (-1) value of cancerous tissue was (3.38±0.15) s(-1). The ratio of T(1) (-1) for normal liver tissues and cancerous liver tissues of the rats investigated is estimated to be 1.9. Since this significant statistical difference, the T(1) (-1) value can be used to distinguish the HCC tissues from normal liver tissues. This method of examining liver and tumor tissues has the advantages of being convenient, easy to operate, and stable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metallic Contaminant detection Systems for Foods and Beverages by High Tc SQUID Magnetic Sensor

A computer controlled contaminant detection systems based on high-Tc Superconducting Quantum Interference Device (SQUID) for food and drink have been designed and constructed. The systems we have developed are the High-Tc SQUID based systems, which are covered with waterproof stainless steel plates and acceptable to HACCP (Hazard Analysis and Critical Control Point) program. One system is for f...

متن کامل

Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device

A spectrometer incorporating a high transition temperature dc superconducting quantum interference device ~SQUID! is used to obtain nuclear magnetic resonance signals from protons in mineral oil at room temperature in fields up to 3 mT. The spatial separation between the SQUID magnetometer at 77 K and the sample at room temperature is less than 1 mm. At 2 mT, the signal is easily resolved in a ...

متن کامل

Computational Investigation on Naphthoquinone Derivatives :Nuclear Magnetic Resonance (NMR) and Quantum mechanic

Naphthoquinones are natural aromatic compounds that can be discovered in various plant families. In recent times a diversity of biological activities of these compounds has been reported. In most cases, these pharmacological activities are related to redox and acid-base properties, which can be modulated synthetically by modifying the substituents attached to the 1, 4- naphthoquinone ring, in o...

متن کامل

NMR and MRI at ultra - low magnetic fields ( Title )

Laser polarized Xe and a high-Tc Superconducting QUantum Interference Device (SQUID) are used to obtain magnetic resonance images in porous materials at a magnetic field of 2.3 mT, corresponding to a Larmor frequency of 27 kHz. Image resolution of 1 mm is obtained with gradients of only 1 mT/m. The resolution of xenon chemical shifts in different physicochemical environments at ultra-low fields...

متن کامل

Development and Applications of SQUIDs in Korea

As sensitive magnetic sensors, magnetometers based on superconducting quantum interference devices can be used for the detection of weak magnetic fields. These signals can be generated by diverse origins, for example, brain electric activity, myocardium electric activity, and nuclear precession of hydrogen protons. In addition, weak current induced in the low-temperature detectors, for example,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012