Architectural analysis of clear corneal incision techniques in cataract surgery using Fourier-domain OCT.

نویسندگان

  • Anderson Teixeira
  • Camila Salaroli
  • Flavio Rezende Filho
  • Francisco Teixeira Pinto
  • Nonato Souza
  • Benedito Antonio Sousa
  • Norma Allemann
چکیده

BACKGROUND AND OBJECTIVE To compare the architecture of single plane self-sealing clear corneal incision (SP-CCI) and shallow grooved self-sealing clear corneal incision (SG-CCI) after cataract surgery using Fourier-domain optical coherence tomography (FD-OCT). PATIENTS AND METHODS An FD-OCT system with a corneal adaptor module was used to image the corneal incisions in radial sections in 44 eyes. A line scan pattern was used to measure the corneal incision, positioning the caliper mark perpendicular to the limbus. Measurements were performed immediately after cataract surgery and at postoperative days 1, 7, and 30. Incisions were analyzed regarding length, location, angle, architecture, and anatomic imperfections. RESULTS All incisions were located superiorly (temporal, 24 eyes; nasal, 20 eyes). The mean SG-CCI length (20 eyes) was 1.79 ± 0.31 mm (range: 0.93-2.64 mm) and the mean incision angle was 37 ± 7 degrees (range: 24-34 degrees). The mean SP-CCI length (22 eyes) was 1.64 ± 0.22 mm (range: 1.25-2.36 mm) and the mean incision angle was 38.5 ± 5 degrees (range: 27-52 degrees) (P < .05). Anatomic imperfections were observed at postoperative day 1 in 19 eyes for SP-CCI and 14 eyes for SG-CCI. No patient presented endophthalmitis during 30 days of follow-up. CONCLUSION Epithelial imperfection at the corneal incision site was observed in more than 36% of the wounds (36% in SP-CCI and 45% in SG-CCI) at postoperative day 1 with spontaneous resolution. SG-CCI had the greatest length and lowest angle of corneal incision. Reduced incision length and inappropriate construction may determine risk factors for wound architectural imperfections. Further studies including more patients with an architectural analysis of clear corneal incisions are needed to confirm these preliminary results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

PURPOSE To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT). SETTING Private practice, Eugene, Oregon, USA. METHODS The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior citizens. The OCT images of the operative eye were taken on the first postop...

متن کامل

Imaging and investigating the effects of incision angle of clear corneal cataract surgery with optical coherence tomography.

Effects of incision angle in construction of clear corneal cataract incision are studied with optical coherence tomography (OCT). A stable incision angle range is found to be existent for single-planed, clear corneal cataract incisions. When well pressurized, incision angles within this stable range result in well-apposed incision edges that resist gapping while incision angles falling outside ...

متن کامل

The evaluation of clear corneal incision architecture using optical coherence tomography

incision used in modern-day phacoemulusification cataract surgery. CCI allows sutureless surgery, induces little astigmatism and provides fast visual rehabilitation1,2. Over the past decade the incidence of endophthalmitis after cataract surgery has increased. There has been much debate on whether the increasing use of clear cornea incision has contributed to this3-5. A recent study speculated ...

متن کامل

Comparison of pre-incision and single-stepped clear corneal incision in phacoemulsification surgery.

AIM To compare postoperative keratometric corneal refractive changes after phacoemulsification surgery between pre-incision and single stepped clear corneal incision techniques. PATIENTS AND METHODS This prospective clinical study included 40 eyes of 40 patients who underwent clear corneal cataract surgery. Twenty eyes were operated using pre-incision technique (Group A), and 20 eyes using si...

متن کامل

Optical coherence tomography of the effects of stromal hydration on clear corneal incision architecture.

PURPOSE To evaluate the effects of stromal hydration on clear corneal incision (CCI) architecture immediately after surgery using anterior segment optical coherence tomography (AS-OCT). SETTING Department of Ophthalmology, Royal Berkshire Hospital, Reading, United Kingdom. METHODS Clear corneal incisions in adult eyes were examined using a Visante AS-OCT imaging system within 1 hour of surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye

دوره 43 6 Suppl  شماره 

صفحات  -

تاریخ انتشار 2012