Neutral-carrier-type potassium ion-selective electrodes based on polymer-supported liquid-crystal membranes for practical use.

نویسندگان

  • Syusuke Oosaki
  • Yoshikazu Kawai
  • Setsuko Yajima
  • Keiichi Kimura
چکیده

Polymer-supported liquid-crystal membranes have been designed for neutral-carrier-type potassium ion-selective electrodes, aiming for practical applications of high-performance liquid-crystalline membrane ion sensors. Two types of polymer-supported liquid-crystal membranes were tested for their usefulness; one is microporous poly(tetra fluoroethylene) (PTFE) membranes impregnated by thermotropic liquid-crystalline compounds, and another is poly(methyl methacrylate) (PMMA) membrane dispersing the same liquid-crystalline compounds. Both of the polymer-supported liquid-crystal membranes containing a liquid-crystalline benzo-15-crown-5 neutral carrier as well as a lipophilic anion excluder work well as ion-sensing membranes for potassium ion-selective electrodes, the ion selectivities of which can be switched by the measurement temperatures. Specifically, PTFE-impregnated liquid-crystal membranes are better than the PMMA-dispersed ones in the sensitivity and selectivity of the resulting ion electrodes. A potassium ion assay in blood sera has proved that neutral-carrier-type ion-selective electrodes based on the polymer-supported liquid-crystal membranes are reliable for practical uses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix

In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...

متن کامل

Strong molecular aggregation of neutral carriers bearing perfluoroalkyl chains in liquid-crystalline ion-sensor membranes.

A liquid-crystalline benzocrown ether, 4'-[(4''-1,1,2,2-tetrahydroperfluorooctyloxy)biphenyloxycarbonyl]benzo-15-crown-5, was used as a neutral carrier of ion-selective electrodes (ISEs) to elucidate the effect of highly ordered assembling of the neutral carrier on the sensor properties through fluorophilic interactions. The properties for the membrane and the resulting ISEs based on a benzocro...

متن کامل

Comparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques

Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

متن کامل

A Study on Neodymium Recovery from Aqueous Solutions for Designing a New Generation of Sandwich Liquid Membrane

Liquid Membrane (LM) based processes, as Supported Liquid Membranes (SLMs), have been proposed, for over 30 years, as effective methods for the selective separation of inorganic/organic species from different water streams. The industrial use of SLMs has been limited mainly by their insufcient stability. To investigate on the main cause of system destabilization and the o...

متن کامل

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 8  شماره 

صفحات  -

تاریخ انتشار 2004