Role of in vivo dosimetry with radiochromic films for dose verification during cutaneous radiation therapy
نویسندگان
چکیده
PURPOSE To evaluate the role of in vivo dosimetry with radiochromic films for dose verification in cutaneous radiation therapy (RT). METHODS Five patients with 8 cutaneous or sub-cutaneous malignancies of the face, neck, trunk and extremity receiving RT were included. Orthovoltage, megavoltage photon therapies were applied based on anatomic location. The delivered dose for each target was measured with GAFCHROMIC EBT3TM film. The differences between the prescribed and measured doses in each target were analyzed based on the RT characteristics, target location and custom patient set up. The accuracy of EBT3TM film measurement was verified by measurements in a solid water phantom. RESULTS The mean measured dose was -3.2% (-9.6% to +2.3%, P=0.86) lower than prescribed over 23 measurements. A wide range of under dose was detected in orthovoltage therapy when a gap existed between skin and a closed-ended applicator surface. The magnitude of the under dosage was correlated with the degree of the gap (P=0.01). The phantom study confirmed the accuracy of GAFCHROMIC EBT3TM film measurement and found that the low measured dose in orthovoltage therapy was caused by the deviation from the inverse square law (ISL) of the beam output at extended source surface distance (SSD) for closed-ended applicators. CONCLUSIONS A significantly low delivered dose for extended SSD orthovoltage therapy was demonstrated during cutaneous RT. The dose fall-off with distance is not completely compensated by the ISL standoff correction for orthovoltage therapy. GAFCHROMIC EBT3™ film is a useful and accurate tool for quality assurance of patients receiving a curative intended cutaneous RT.
منابع مشابه
Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...
متن کاملVerification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...
متن کاملIn vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment
Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evaluate the actual radiation dose delivered to the target. A practical method for ...
متن کاملComparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation
Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...
متن کاملSkin Dosimetry in Radiotherapy of Breast Cancer: a Comparison between EBT and EBT3 Radiochromic Films
Objective: Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer.Methods: A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT3...
متن کامل