Global endocardial electrical restitution in human right and left ventricles determined by noncontact mapping.

نویسندگان

  • Arthur M Yue
  • Michael R Franz
  • Paul R Roberts
  • John M Morgan
چکیده

OBJECTIVES This study was aimed at evaluating global characteristics of electrical restitution in the human ventricle using noncontact mapping. BACKGROUND Steep action potential restitution (slope >1) and conduction velocity (CV) restitution have been linked with propensity to ventricular fibrillation, but clinical measurement of global electrical restitution had not been feasible. METHODS Activation-recovery interval (ARI) and CV restitution curves were simultaneously constructed from 16 regional segments of the left and right ventricles in 8 patients (6 male, 2 female, age 42 +/- 17 years) following successful ablation of idiopathic ventricular tachycardia in the absence of structural disease guided by the Ensite 3000 system (Endocardial Solutions Inc., St. Paul, Minnesota). The ARIs were determined from reconstructed unipolar electrograms as validated with monophasic action potential recordings. The ARI restitution slopes were determined using the overlapping least-squares linear segments. RESULTS Global electrical restitution curves were heterogeneous in shape and distribution. ARI restitution slope was >1 at 25% of 128 sites. The overall mean slope was 0.79 and was greater in the left than the right ventricle (0.93 +/- 0.49 vs. 0.65 +/- 0.26, p < 0.001). Dispersion of ARI restitution slopes increased with decreasing diastolic intervals. The CV restitution operated over a narrower range of diastolic intervals compared with ARI restitution, reaching a plateau (10 +/- 6 ms vs. 38 +/- 13 ms, p < 0.001) after refractoriness. The magnitude of CV restitution was also greater (steeper) than ARI restitution (25 +/- 10% vs. 18 +/- 9%, p < 0.001). CONCLUSIONS Noncontact mapping can be used to examine global electrical restitution in the human ventricle. The ARI restitution is heterogeneous, with a slope >1 at 25% of all sites. The heterogeneity of ARI and CV restitution may be important in determining myocardial electrical stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of human ventricular repolarization by noncontact mapping: validation with monophasic action potential recordings.

BACKGROUND Noncontact mapping (NCM) has not been validated as a clinical technique to measure ventricular repolarization. We used NCM to determine repolarization characteristics by analysis of reconstructed unipolar electrograms (UEs) at the same sites as monophasic action potential (MAP) recordings in the human ventricle. METHODS AND RESULTS MAPs were recorded from a total of 355 beats at 46...

متن کامل

Simultaneous Epicardial and Noncontact Endocardial Mapping of the Canine Right Atrium: Simulation and Experiment

Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activi...

متن کامل

Dynamic restitution of action potential duration during electrical alternans and ventricular fibrillation.

The restitution kinetics of action potential duration (APD) were investigated in paced canine Purkinje fibers (P; n = 9) and endocardial muscle (M; n = 9), in isolated, perfused canine left ventricles during ventricular fibrillation (VF; n = 4), and in endocardial muscle paced at VF cycle lengths (simulated VF; n = 4). Restitution was assessed with the use of two protocols: delivery of a single...

متن کامل

Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter: comparison of contact and reconstructed electrograms during sinus rhythm.

BACKGROUND Catheter ablation of ventricular tachycardia is limited in part by difficulty in identifying suitable sites for ablation. A noncontact multielectrode array (MEA) has been developed that allows reconstruction of 3360 electrograms, using inverse-solution mathematics, that are superimposed onto a computer-simulated model of the endocardium. This study assesses the accuracy of timing and...

متن کامل

Validation of a new noncontact catheter system for electroanatomic mapping of left ventricular endocardium.

BACKGROUND Improvements in cardiac mapping are required to advance our understanding and treatment of arrhythmias. This study validated a new noncontact multielectrode array catheter and accompanying analysis system to provide electroanatomic mapping of the entire left ventricular (LV) endocardium during a single beat. METHODS AND RESULTS A 9F 64-electrode balloon array catheter with an infla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2005