An Innovative Bipolar Instrument for Laparoscopic Surgery
نویسندگان
چکیده
OBJECTIVE Bipolar electrosurgery is an excellent method for obtaining hemostasis at laparoscopy. The present study describes and evaluates a bipolar device that can be more versatile and cost effective in advanced operative procedures than the traditional instrumentation. METHODS This was a retrospective, case-controlled analysis of bipolar instrumentation with a design classification of II-2. A single surgeon in a private practice setting performed all procedures. Sixteen patients, matched for age and pathology were evaluated by videotape review to determine the comparative efficiency of the BiCOAG bipolar dissector/grasper versus traditional Kleppinger bipolar forceps. Efficiency here is defined as comparative operating times in each group. RESULTS The number of instrument changes per case was counted because this appeared to be the only variable other than time that differentiated the 2 groups. The BiCOAG bipolar dissector/grasper device group had 4 times fewer instrument changes and significantly decreased operating room times when compared with that of the Kleppinger forceps group. Because cost per unit of operating room time was a constant figure, the decrease in cost that resulted due to the decrease in operating time is considered a cost-effective measure. CONCLUSIONS The BiCOAG bipolar dissector/grasper is a cost-effective, efficient instrument for use in operative laparoscopic procedures.
منابع مشابه
The Twin Forceps: A New Instrument for SILS
In the last ten years, the single incision laparoscopic surgery (SILS) is gaining more interest than the traditional laparoscopic surgery (LAP). Many studies make a comparison between the performances of the SILS and the LAP. The results show that the single incision laparoscopic surgery reduces pain, length of period of postoperative hospitalization, and loss of blood. This technique is also a...
متن کاملComparison of Mono and Bipolar Electrocoagulation in Laparoscopic Ovariohysterectomy in Dogs
Objective- To evaluate the clinical safety and superiority of monopolar and bipolar electrocauter in laparoscopic ovariohysterectomy in dogs. Design-Elective experimental study Animals- Twenty four mixed breed healthy adult female dogs. Procedures-The dogs divided into two equal groups. Laparoscopic ovariohysterectomy performed using either monopolar (n=12) or bipolar (n=12) electrocoagulati...
متن کاملMinimally invasive total splenectomy in dogs: A clinical report
Cases of minimally-invasive surgery are gaining acceptance among surgeons and animal owners. One type of minimally-invasive surgery is total splenectomy, which is indicated for splenic tumors, trauma, torsions, and for dogs that require blood transfusion. To assess the safety of the technique, experimental laparoscopic splenectomies were performed in dogs for the first time in Iran. Three adult...
متن کاملNumerical Modeling of an Innovative Bipolar Plate Design Based on the Leaf Venation Patterns for PEM Fuel Cells
Flow channel design on bipolar plates has a direct effect on Proton Exchange Membrane (PEM) fuel cell performance. It has been found out that the flow field design has a deterministic role on the mass transport and water management, and therefore on the achieved power in PEM Fuel cells. This study concentrates on improvements in the fuel cell performance through optimization of channel dimensio...
متن کاملLaparoscopic Colon Surgery for Benign Disease: A Comparison to Open Surgery
Backgrounds and Objectives: Today we are witnessed a growing number of minimally invasive surgical techniques for different diseases. Laparoscopic colon surgery as a minimally invasive surgery is currently growing in treatment of malignancies after proving his place in the treatment of benign diseases. We compare in this study results of laparoscopic colorectal surgery with open surgery. Method...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2005