Diagnosis of brain death by transcranial Doppler sonography.
نویسندگان
چکیده
Delays in diagnosis of brain death have definite consequences for the organ retrieval and transplantation process. It is advisable to use accurate diagnostic methods. Transcranial Doppler sonography is a well-accepted technique for diagnosing cerebral circulatory arrest. However, in some cases, the access to the intracranial circulation via the temporal window is difficult. In 43 brain-dead patients we evaluated the rate of impossibility of insonation of middle cerebral artery using a temporal window and the usefulness of an orbital window for insonation of the carotid siphon. In 39 patients the usual protocol of insonation (temporal window and foramen magnum window) was sufficient to demonstrate cerebral circulatory arrest. In 10 patients, including all the cases in which it was impossible to use a temporal approach, the carotid siphon was successfully insonated, showing in all the cases the existence of a sonographic pattern compatible with cerebral circulatory arrest. It may be concluded that the use of an orbital window for exploring intracranial circulation by transcranial Doppler sonography can be a useful tool in cases of difficult sonic windows.
منابع مشابه
Diagnosis of brain death by transcranial Doppler sonography
The blood flow velocities in the basal cerebral arteries can be recorded at any age by transcranial Doppler sonography. We examined nine children with either initial or developing clinical signs of brain death. Soon after successful resuscitation increased diastolic flow velocities indicated a probable decrease in cerebrovascular resistance; this was of no particular prognostic importance. As s...
متن کاملCoregistration of transcranial Doppler - sonography and EEG in the diagnostic procedures of detection of brain death
Brain death (BD) diagnosis is the clinical assessment of the irreversible loss of function of the entire brain, including the brainstem. Transcranial Doppler (TCD) examination is used in several countries as a confirmatory test to assess cerebral circulatory arrest (CCA), but is not feasible in patients with absent temporal bone windows. TCD is highly specific, but less sensitive because of fal...
متن کاملTranscranial doppler sonography diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine
Background: An imbalance of the cerebrovascular response during functional activation of the brain has been postulated as a factor in the pathophysiology of migraine. The purpose of this study was to determine the transcranial doppler sonography (TDS) diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine. Methods: This study was carried out on 46 pa...
متن کاملDiagnosis of brain death by transcranial
The blood flow velocities in the basal cerebral arteries can be recorded at any age by transcranial Doppler sonography. We examined nine children with either initial or developing clinical signs of brain death. Soon after successful resuscitation increased diastolic flow velocities indicated a probable decrease in cerebrovascular resistance; this was of no particular prognostic importance. As s...
متن کاملCerebral Circulatory Arrest Detected by Transcranial Color-Coded Duplex Sonography: A Feasible Diagnosis for Intensivists.
Brain death is clinically diagnosed by verification of the absence of brain stem reflexes, motor responses, and the ventilatory drive.1 In some circumstances, ancillary tests are necessary to confirm the diagnosis of brain death, especially when there is uncertainty about the reliability of parts of the neurologic examination or when an apnea test cannot be performed. Ancillary tests are also u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Transplantation proceedings
دوره 36 10 شماره
صفحات -
تاریخ انتشار 1988