Electrical nerve localization: effects of cutaneous electrode placement and duration of the stimulus on motor response.
نویسندگان
چکیده
BACKGROUND Recommendations regarding the technical aspects of nerve stimulator-assisted nerve localization are conflicting. The objectives of this study were to determine whether the placement of the cutaneous electrode affects nerve stimulation and to determine the duration and intensity of an electrical stimulus that allows nerve stimulation with minimal discomfort. METHODS Ten healthy volunteers underwent an interscalene and a femoral nerve block. After obtaining a clearly visible motor response of the biceps (interscalene) and quadriceps (femoral) muscles at the minimal current (0.1 ms, 2 Hz), the position of the cutaneous electrode was varied. Next, the duration of the stimulating current was set at 0.05, 0.1, 0.3, 0.5, or 1.0 ms, in random order. Intensity of the motor response and discomfort on stimulation were recorded. RESULTS The minimal current at which a visible motor response was obtained was 0.32 +/- 0.1 mA (0.23-0.38 mA) for the inter-scalene block and 0.29 +/- 0.1 mA (0.15-0.4 mA) for the femoral block. Changing the position of the return electrodes did not result in any change in the grade of the motor response or in the current required to maintain it. Currents of longer duration caused discomfort and more forceful contraction at a lower current intensity as compared with currents of shorter duration (P < 0.01). When the current was adjusted to maintain the same visible motor response, there was no significant discomfort among studied current durations. CONCLUSION Site of placement of the cutaneous electrode is not important when constant current nerve stimulators are used during nerve localization in regional anesthesia. There is an inverse relation between the current required to obtain a visible motor response and current duration. Selecting a current duration between 0.05 and 1.0 ms to specifically stimulate sensory or motor components of a mixed nerve does not seem to be important in clinical practice.
منابع مشابه
Extraction of Sensory part of Ulnar Nerve Signal Using Blind Source Separation Method
A recorded nerve signal via an electrode is composed of many evokes or action potentials, (originated from individual axons) which may be considered as different initial sources. Recovering these primitive sources in its turn may lead us to the anatomic originations of a nerve signal which will give us outstanding foresights in neural rehabilitations. Accordingly, clinical interests may be r...
متن کاملMEDIAN NERVE STIMULATION PO TENTIATES THE MU SCLE RESPONSES TO TRANS C RANIAL MAGNETIC STIMULATION
Motor responses evoked by transcranial magnetic stimulation OMS) or transcranial electrical stimulation (TCS) can be facilitated by a prior conditioning stimulus to an afferent nerve. Two facilitation periods are described short (SI), when the nerve stimulus is given near 0 to 10 ms after cranial stimulation, and long (LI), when nerve stimulation is given 25-60 ms before the cranial stimula...
متن کاملComparison of the effect of quasitrapezoidal and rectangular pulses on bio- electrical activity, calcium spike properties and afterhyperpolarization potentials of Fl cells of Helix aspersa using intracellular recording
While the effect of changes of stimulus waveform (quasitrapezoidal and rectangular current pulses) on nerve activation is clear, but there is no evidence on the effect of quasitrapezoidal pulses on ionic currents of cellular membrane. In the present study, the effect of depolarizing quasi-trapezoidal current pulses, in comparison with that of depolarizing rectangular current pulses, on firing...
متن کاملEffects of Black Scorpion Androctonus crasicuda Venom on Striated Muscle Preparation in vitro.
Effects of venom from black scorpion Androctonus crasicuda (AC) were determined on isolated chick biventer cervices nerve-muscle and mouse hemidiaphragm preparations using twitch tension method. The isolated nerves were stimulated by electrical stimulator and response to each stimulus was recorded. The venom mainly acted prejunctionally to facilitate neuromuscular activity due to an increase in...
متن کاملEffects of Black Scorpion Androctonus crasicuda Venom on Striated Muscle Preparation in vitro.
Effects of venom from black scorpion Androctonus crasicuda (AC) were determined on isolated chick biventer cervices nerve-muscle and mouse hemidiaphragm preparations using twitch tension method. The isolated nerves were stimulated by electrical stimulator and response to each stimulus was recorded. The venom mainly acted prejunctionally to facilitate neuromuscular activity due to an increase in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 100 6 شماره
صفحات -
تاریخ انتشار 2004