High-Resolution Imaging of Parafoveal Cones in Different Stages of Diabetic Retinopathy Using Adaptive Optics Fundus Camera
نویسندگان
چکیده
PURPOSE To assess cone density as a marker of early signs of retinopathy in patients with type II diabetes mellitus. METHODS An adaptive optics (AO) retinal camera (rtx1™; Imagine Eyes, Orsay, France) was used to acquire images of parafoveal cones from patients with type II diabetes mellitus with or without retinopathy and from healthy controls with no known systemic or ocular disease. Cone mosaic was captured at 0° and 2°eccentricities along the horizontal and vertical meridians. The density of the parafoveal cones was calculated within 100×100-μm squares located at 500-μm from the foveal center along the orthogonal meridians. Manual corrections of the automated counting were then performed by 2 masked graders. Cone density measurements were evaluated with ANOVA that consisted of one between-subjects factor, stage of retinopathy and the within-subject factors. The ANOVA model included a complex covariance structure to account for correlations between the levels of the within-subject factors. RESULTS Ten healthy participants (20 eyes) and 25 patients (29 eyes) with type II diabetes mellitus were recruited in the study. The mean (± standard deviation [SD]) age of the healthy participants (Control group), patients with diabetes without retinopathy (No DR group), and patients with diabetic retinopathy (DR group) was 55 ± 8, 53 ± 8, and 52 ± 9 years, respectively. The cone density was significantly lower in the moderate nonproliferative diabetic retinopathy (NPDR) and severe NPDR/proliferative DR groups compared to the Control, No DR, and mild NPDR groups (P < 0.05). No correlation was found between cone density and the level of hemoglobin A1c (HbA1c) or the duration of diabetes. CONCLUSIONS The extent of photoreceptor loss on AO imaging may correlate positively with severity of DR in patients with type II diabetes mellitus. Photoreceptor loss may be more pronounced among patients with advanced stages of DR due to higher risk of macular edema and its sequelae.
منابع مشابه
Analysis of retinal capillaries in patients with type 1 diabetes and nonproliferative diabetic retinopathy using adaptive optics imaging.
PURPOSE To illustrate a noninvasive method to analyze the retinal capillary lumen caliber in patients with Type 1 diabetes. METHODS Adaptive optics imaging of the retinal capillaries were acquired in two parafoveal regions of interest in eyes with nonproliferative diabetic retinopathy and unaffected controls. Measures of the retinal capillary lumen caliber were quantified using an algorithm w...
متن کاملApplication of adaptive optics in retinal imaging: A quantitative and clinical comparison with standard cameras
Aim: The objective of this project was to evaluate high resolution images from an adaptive optics retinal imager through comparisons with standard film-based and standard digital fundus imagers. Methods: A clinical prototype adaptive optics fundus imager (AOFI) was used to collect retinal images from subjects with various forms of retinopathy to determine whether improved visibility into the di...
متن کاملRetinal Damage in Chloroquine Maculopathy, Revealed by High Resolution Imaging: A Case Report Utilizing Adaptive Optics Scanning Laser Ophthalmoscopy
A 53-year-old Asian woman was treated with hydroxychloroquine and chloroquine for lupus erythematosus. Within a few years, she noticed circle-shaped shadows in her central vision. Upon examination, the patient's visual acuity was 20 / 25 in both eyes. Humphrey visual field (HVF) testing revealed a central visual defect, and fundoscopy showed a ring-shaped area of parafoveal retinal pigment epit...
متن کاملVariability in parafoveal cone mosaic in normal trichromatic individuals
Parafoveal function is important for daily visual tasks such as reading. Here the variability in cone density along the four cardinal meridians in parafoveal regions of the retina was investigated in vivo using an adaptive optics fundus camera. Ten healthy normal trichromatic individuals were included in the study. There were significant differences in cone density between individuals at all fo...
متن کاملFine structure in diabetic retinopathy lesions as observed by adaptive optics imaging. A qualitative study.
PURPOSE Diabetic retinopathy is diagnosed by fundus photography and optical coherence tomography (OCT) scanning. However, adaptive optics (AO) imaging can be expected to add new aspects to the knowledge of diabetic retinopathy because photographic resolution is improved by reducing the influence of optical aberrations on retinal imaging. METHODS Nineteen patients with diabetes mellitus were s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016