Carbon dioxide contrast agent for CT arteriography: results in a porcine model.

نویسندگان

  • Andreas H Mahnken
  • Philipp Bruners
  • Gottfried Mommertz
  • Georg Mühlenbruch
  • Michael J Jacobs
  • Rolf W Günther
  • Stephan Langer
چکیده

PURPOSE To test the feasibility of carbon dioxide (CO(2))-enhanced computed tomographic (CT)-arteriography in an animal model. MATERIALS AND METHODS Five domestic swine underwent digital subtraction angiography (DSA), conventional CT angiography with iodinated contrast material, and CO(2)-enhanced CT arteriography. For each CO(2)-enhanced DSA image series, 100 mL of pressurized CO(2) was injected at 1.3 bar. CT imaging was performed according to a standardized scan protocol (2 x 32 x 0.6 mm; 120 kV, 210 mAs(eff), 330 msec gantry rotation time). Iodinated contrast material was administered intravenously according to a biphasic injection protocol. For CO(2)-enhanced CT arteriography, CO(2) was administered intraarterially via a catheter placed in the juxtarenal aorta. An injection pressure of 0.65 bar (volume flow rate, 7.5 mL/sec) was applied. Images were assessed visually by two observers on a four-point grading scale. Absolute intraarterial attenuation values were measured. RESULTS Image quality was rated to be the best for standard DSA. CO(2)-enhanced DSA was rated slightly superior to CO(2)-enhanced CT arteriography. No examination was considered to be nondiagnostic. The average multislice spiral CT (MSCT) scan duration was 7.9 sec +/- 0.6. The average amount of gas required for CO(2)-enhanced CT arteriography was 104 mL +/- 4, compared with 400 mL for CO(2)-enhanced DSA. Absolute attenuation values were significantly higher with CO(2)-enhanced CT arteriography (aorta, -928 HU +/- 39) than with standard CT angiography (490 HU +/- 40; P < .0001). CONCLUSIONS CO(2)-enhanced CT arteriography is feasible. In a porcine model, this technique is capable of depicting the aortoperipheral vessels down to the lower limb. These results warrant further studies of the diagnostic value of CO(2)-enhanced MSCT arteriography for the detection of arterial pathologic processes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon Dioxide Angiography: Scientific Principles and Practice

Carbon dioxide (CO2) is a colorless, odorless gas which occurs naturally in the atmosphere and human body. With the advent of digital subtraction angiography, the gas has been used as a safe and useful alternative contrast agent in both arteriography and venography. Because of its lack of renal toxicity and allergic potential, CO2 is a preferred contrast agent in patients with renal failure or ...

متن کامل

Carbon dioxide arteriography as a supplementary study in the detection of acute massive gastrointestinal bleeding

Purpose: To compare the diagnostic efficiency of carbon dioxide (CO2) and an iodinated contrast medium (ICM) for detection of arterial haemorrhage. Methods and materials: Over a 24-month period, 23 patients were referred 26-times for angiography to detect arterial gastrointestinal haemorrhage. The CO2 arteriography was performed only when standard ICM arteriography was undetermined or negative....

متن کامل

Modeling and Experimental Study of Carbon Dioxide Absorption in a Flat Sheet Membrane Contactor

comIn the present study, CO2 removal from natural gas stream has been studied using a flat sheet membrane contactor. A three dimensional mathematical model is developed to describe the process. The model considers the transport of a gas mixture containing carbon dioxide and methane through a flat sheet membrane contactor module. The model is based on the non-wetted mode of operation, in which t...

متن کامل

Novel use of carbon dioxide arteriography in renal artery pseudoaneurysm in patients with poor renal function.

Renal artery pseudoaneurysm (RAP) is a rare complication of partial nephrectomy, but is usually effectively managed with renal vessel embolisation. We report a particularly challenging case of a patient with chronic kidney disease (CKD) who developed a RAP following a laparoscopic heminephrectomy and was treated using superselective renal vessel coil embolisation with carbon dioxide (CO2) as th...

متن کامل

Carbon dioxide as a substitute for iodine contrast in arteriography during embolectomy

Acute limb ischemia can be potentially harmful to the limb and life threatening. Renal failure is a possible outcome associated with release of products of ischemic limb reperfusion. Some authors reported the benefit of performing angiography after embolectomy, even though iodine contrast is also nephrotoxic. We report a case of embolectomy on a patient with renal insufficiency in whom carbon d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 2008