Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12)
نویسندگان
چکیده
Thoracic cortical bone trajectory (CBT) screw fixation can maximize the thread contact with cortical bone, and it is 53.8% higher than that of the traditional pedicle screws. Moreover, it can also enable less tissue dissection and retraction for reduced muscle disruption.Eighty pediatric patients are divided into 4 age groups and their thoracic vertebrae are analyzed on computed tomography (CT) images. The maximal screw length, maximal screw diameter, screw diameter, and the cephalad angle are measured. The statistical analysis is performed using the Student's t-test and Pearson's correlation analysis.Maximal screw length increases from T9 to T12 and there are significant differences between girls and boys at T9, T10, T11, and T12 in majority of groups (P < 0.05). The maximal screw diameter and screw diameter increase from T9 to T12. The maximal screw diameter ranges from 6.27 mm to 10.20 mm, whereas the screw diameter ranges from 3.87 mm to 6.75 mm. Meanwhile, the maximum cephalad angle is 23.06° and the minimum is 13.11°. No statistically significant differences in the cephalad angle are found at all levels.Our study establishes the feasibility of 4.5 to 5.5 mm CBT screws fixation via pedicle or pedicle rib unit in the pediatric thoracic spine. The entry point of the pediatric thoracic CBT screws is 6 o'clock orientation of the pedicle. Findings of our study also provide insights into the screw insertion angle and screw size decision.
منابع مشابه
Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine.
While the biomechanical properties of pedicle screws have proven to be superior in the lumbar spine, little is known concerning pullout strength of pedicle screws in comparison to hooks in the thoracic spine. In vitro biomechanical pullout testing was performed to evaluate the axial pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine with regard to surgical...
متن کاملCortical bone trajectory screws for the middle-upper thorax
To quantify the reference data concerning the morphometrics of the middle-upper thorax to guide the placement of cortical bone trajectory (CBT) screws.Eighty patients were studied on computed tomography (CT) scans. The reference anatomical parameters were measured. Next, 20 cadaveric specimens were implanted with CBT screws based on CT measurements. These specimens were then judged directly fro...
متن کاملCadaver training module for teaching thoracic pedicle screw placement to residents.
Surgical training using simulators has been shown to be highly effective but is not available for some applications and is too expensive for many programs. The authors piloted a cadaver-based module with the goal of objectively measuring and significantly improving orthopedic residents' surgical skills in placing thoracic pedicle screws, an advanced procedure. An experienced spine surgeon place...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملPercutaneous lumbar and thoracic pedicle screws: a trauma experience.
DESIGN Retrospective case study. OBJECTIVE Percutaneous pedicle screw (PPS) techniques do not allow direct visualization and may lead to erroneous screw placement. A technique utilizing only fluoroscopy is described. Verification of its accuracy and morphometric validation are presented. BACKGROUND Minimally invasive spine surgical techniques, particularly PPS placement, have been growing i...
متن کامل