Comparing methods of measurement: why plotting difference against standard method is misleading.
نویسندگان
چکیده
When comparing a new method of measurement with a standard method, one of the things we want to know is whether the difference between the measurements by the two methods is related to the magnitude of the measurement. A plot of the difference against the standard measurement is sometimes suggested, but this will always appear to show a relation between difference and magnitude when there is none. A plot of the difference against the average of the standard and new measurements is unlikely to mislead in this way. We show this theoretically and by a practical example.
منابع مشابه
Comparisons against baseline within randomised groups are often used and can be highly misleading
BACKGROUND In randomised trials, rather than comparing randomised groups directly some researchers carry out a significance test comparing a baseline with a final measurement separately in each group. METHODS We give several examples where this has been done. We use simulation to demonstrate that the procedure is invalid and also show this algebraically. RESULTS This approach is biased and ...
متن کاملمقایسه روشهای مختلف اندازهگیری گچ در برخی خاکهای اصفهان
Gypsum affects many physical, chemical and mineralogical properties which in turn influences management, classification and sutability of the soils. This is the reason why accurate measurement of gypsum in soil is very important. In most of the soil science laboratories, the method of acetone ,in spite of its too much limitation, is being used as a standard method. The purpose of this researc...
متن کاملمقایسه روشهای مختلف اندازهگیری گچ در برخی خاکهای اصفهان
Gypsum affects many physical, chemical and mineralogical properties which in turn influences management, classification and sutability of the soils. This is the reason why accurate measurement of gypsum in soil is very important. In most of the soil science laboratories, the method of acetone ,in spite of its too much limitation, is being used as a standard method. The purpose of this researc...
متن کاملComparing transcutaneous bilirubin versus serum bilirubin measurement using spectrophotometry for jaundice screening of full-term neonates
Background: Neonatal jaundice is an almost common problem among neonates that may cause complications such as kernicterus in severe cases. Since early diagnosis and proper treatment of neonatal jaundice is vital to prevent the related complications, it is necessary to check bilirubin before discharging the neonates. There are several evaluating and diagnostic methods to measure the level of bil...
متن کاملDetermining Difference in Evolutionary Variation of Bacterial RecA proteins vs 16SrRNA Genes by using 16s_Toxonomy Tree
Background and Aims: The rate of variation in various genes of a bacterial species is different during evolution. Therefore, in systematic bacterial studies many researchers compare the phylogenetic tree of a particular gene to the standard tree of an rRNA gene. Regarding the importance of 16SrRNA gene and the evolutional process of RecA protein family, we investigated the changes in the select...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lancet
دوره 346 8982 شماره
صفحات -
تاریخ انتشار 1995