Cortical Shift Tracking Using a Laser Range Scanner and Deformable Registration Methods
نویسندگان
چکیده
A novel brain shift tracking protocol is introduced in this paper which utilizes laser range scan (LRS) data and 2D deformable image registration. This protocol builds on previous efforts to incorporate intra-operative LRS data into a model-updated image guided surgery paradigm for brain shift compensation. The shift tracking method employs the use of a LRS system capable of capturing textures of the intra-operative scene during range data acquisition. Textures from serial range images are then registered using a 2D deformable registration approach that uses local support radial basis functions and mutual information. Given the deformation field provided by the registration, 3D points in serial LRS datasets can then be tracked. Results from this paper indicate that the error associated with tracking brain movement is 1.1mm on average given brain shifts of approximately 20.5mm. Equally important, a strategy is presented to rapidly acquire intra-operative measurements of shift which are compatible with model-based strategies for brain deformation compensation.
منابع مشابه
Textured laser range scanning and registration of the cortical surface
A novel method for intra-operative data acquisition using a laser range scanner is presented for applications in model-updated image-guided surgery. The scanner produces a point cloud containing true-color encoded range data of its field-of-view. This allows characterization of intra-operative conditions using both intensity and geometry information. Furthermore, a rigid-body registration algor...
متن کاملAutomatic segmentation of cortical vessels in pre- and post- tumor resection laser range scan images
Measurement of intra-operative cortical brain movement is necessary to drive mechanical models developed to predict sub-cortical shift. At our institution, this is done with a tracked laser range scanner. This device acquires both 3D range data and 2D photographic images. 3D cortical brain movement can be estimated if 2D photographic images acquired over time can be registered. Previously, we h...
متن کاملIncorporation of a laser range scanner into an image-guided surgical system
Laser range scanners provide rapid and accurate non-contact methods for acquiring three-dimensional surface data, offering many advantages over other techniques currently available during surgery. The range scanner was incorporated into our image-guided surgery system to augment registration and deformation compensation. A rigid body, embedded with infrared diodes, was attached to the scanner f...
متن کاملIncorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking.
As image guided surgical procedures become increasingly diverse, there will be more scenarios where point-based fiducials cannot be accurately localized for registration and rigid body assumptions no longer hold. As a result, procedures will rely more frequently on anatomical surfaces for the basis of image alignment and will require intraoperative geometric data to measure and compensate for t...
متن کاملIntraoperative cortical surface characterization using laser range scanning: preliminary results.
OBJECTIVE To present a novel methodology that uses a laser range scanner (LRS) capable of generating textured (intensity-encoded) surface descriptions of the brain surface for use with image-to-patient registration and improved cortical feature recognition during intraoperative neurosurgical navigation. METHODS An LRS device was used to acquire cortical surface descriptions of eight patients ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 2879 شماره
صفحات -
تاریخ انتشار 2003