Lack of improvement of lung diffusing capacity following fluid withdrawal by ultrafiltration in chronic heart failure.

نویسندگان

  • P G Agostoni
  • M Guazzi
  • M Bussotti
  • M Grazi
  • P Palermo
  • G Marenzi
چکیده

OBJECTIVES We sought to investigate the possibility that lung diffusing capacity reduction observed in chronic heart failure is reversible in the short term. BACKGROUND Mechanical properties of the lung usually ameliorate with antifailure treatment including drugs, ultrafiltration and heart transplantation, whereas lung diffusion rarely improves. METHODS We studied the mechanical properties of the lung (pulmonary function tests with determination of alveolar volume, extravascular lung fluids and lung tissue), lung diffusion for carbon monoxide (DLco), including membrane diffusing capacity (Dm), pulmonary capillary blood volume (Vc) and pulmonary hemodynamics, in 28 patients with stable chronic heart failure, before a single session of extracorporeal ultrafiltration (3,973 +/- 2200 ml) and four days thereafter. Lung mechanics and diffusion were also evaluated in 18 normal subjects. RESULTS Vital capacity, forced expiratory volume (1 s) and maximal voluntary ventilation were lower in patients when compared with normal subjects, and increased after ultrafiltration from 2.1 +/- 0.7 to 2.5 +/- 0.7(1)*, 1.7 +/- 0.5 to 2.0 +/- 0.6(1)* and 67 +/- 25 to 79 +/- 26 (1/min)*, respectively (* p < 0.02 vs. pre-ultrafiltration). Post-ultrafiltration alveolar volume was augmented, while lung tissue, body weight (approximately 6 kg), chest X-ray extravascular lung water score and pulmonary vascular pressure were reduced. Heart dimensions (echocardiography) remained unchanged. DLco, Dm and Vc were 29.0 +/- 5.0 ml/min/mm Hg, 47.0 +/- 11.0 ml/min/mm Hg, 102 +/- 20 ml in normal subjects and 17.1 +/- 4.0#, 24.1 +/- 6.5#, 113 +/- 38 and 17.0 +/- 5.0#, 24.8 +/- 7.9#, 100 +/- 39 in patients before and after ultrafiltration, respectively (# = p < 0.01 vs. controls). CONCLUSIONS In chronic heart failure, ultrafiltration improves volumes and mechanical properties of the lung by reducing lung fluids. Diffusion is unaffected by ultrafiltration, suggesting that, in chronic heart failure, the alveolar-capillary membrane abnormalities are fluid-independent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of diuresis on extravascular lung water and pulmonary function in acute decompensated heart failure

AIMS The effect of extravascular lung water (EVLW) and relationship to functional status as a result of acute decompensated heart failure (ADHF) are not well understood. We sought to quantify changes in clinical variables, EVLW, airway anatomy, spirometry, and diffusing capacity for carbon monoxide before and after treatment for ADHF. METHODS AND RESULTS Fifteen patients were recruited within...

متن کامل

The Role of EDD (Exercise Capacity, Dyspnea, and Diffusing Capacity of Lungs for Carbon Monoxide) Index in Pulmonary Fibrosis Secondary to Scleroderma

Introduction: Pulmonary involvement secondary to Systemic Sclerosis (SSc) is the major cause of morbidity and mortality in SSc patients. We designed this study to determine the correlation of important lung function parameters with lung High Resolution CT (HRCT) scan findings. Materials and Methods: Thirty–two consecutive diffuse SSc patients with pulmonary fibrosis were enrolled in this cross...

متن کامل

Atrial fibrillation: one more sporting inconvenience?

Costello O, West JB. Short-term reversibility of ultrastructural changes in pulmonary capillaries caused by stress failure. J Appl Physiol 1992; 73: 1150–8. [12] Kay JM, Edwards FR. Ultrastructure of the alveolar-capillary wall in mitral stenosis. J Pathol 1973; 111: 239–45. [13] Lee YS. Electron microscopic studies on the alveolar-capillary barrier in the patients of chronic pulmonary edema. J...

متن کامل

Ultrafiltration in the management of refractory congestive heart failure.

Ultrafiltration was performed in nine patients with congestive cardiac failure that was refractory to conventional medical treatment. A mean of 12 X 7 litres of fluid was removed, and there was a sustained symptomatic improvement in all patients. Weight loss continued after ultrafiltration and a sustained increase in serum sodium concentration was also noted. A transient fall in right atrial pr...

متن کامل

Angiotensin-converting enzyme inhibition restores the diffusing capacity for carbon monoxide in patients with chronic heart failure by improving the molecular diffusion across the alveolar capillary membrane.

Conductance of alveolar capillary membrane (DM) and capillary blood volume (VC) are the subcomponents of the pulmonary diffusing capacity for carbon monoxide (DLCO). In chronic heart failure, stress failure of the membrane provides a mechanism for reduced DM and subsequent impairment of DLCO. Angiotensin-converting enzyme inhibition improves DLCO in patients with chronic heart failure. This stu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2000