A Cross-sectional Analysis of Glove Perforation in Primary and Revision Total Hip Arthroplasty

نویسندگان

  • D Kumar
  • K Shantanu
  • M Kumar
  • A Kumar
  • V Sharma
چکیده

The number of total hip arthroplasties is ever increasing. Literature about glove perforation rates in arthroplasties in India is very scarce. The purpose of our study was to determine the incidence of glove perforation and increasing the awareness of possible glove perforations to decrease the risk of infection. We performed a prospective study in which we tested gloves worn by all scrubbed personnel. A total of 1408 gloves were collected from 42 primary total hip and 13 revision total hip arthroplasties. Incidence of glove perforation was found to be more in revision total hip arthroplasty. We found a greater outer glove perforation rate of about 38.33% as compared to 25 % inner glove perforation rate. Outer glove perforation was recognized 100% of time intraoperatively but inner glove perforation was noted only 17% of time. First assistant recorded highest rate of glove perforation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective analysis of glove perforation in primary and revision total hip and total knee arthroplasty.

Literature in regard to glove perforation rates in revision total joint arthroplasty (TJA) is scarce. Our purpose was to determine the incidence of perforation in revision TJA. Gloves from all scrubbed personnel were tested based on the American Society for Testing and Materials. A total of 3863 gloves were collected from 58 primary and 36 revision arthroplasty cases. Surgeons had a 3.7% outer-...

متن کامل

The protective effect of a cut-resistant glove liner.

We performed a prospective, randomised study comparing the rates of glove perforation using double latex gloving with or without a disposable protective glove liner (Paraderm) on 118 patients undergoing primary or revision arthroplasty of the hip or knee by one surgeon (FRH). The patients were randomly allocated into two groups: in group 1 an inner and outer pair of latex gloves were worn as do...

متن کامل

Study of Glove Perforation during Hip Replacement Arthroplasty: Its Frequency, Location, and Timing

Objective. The aim of the study was to evaluate the location, timing, and frequency of glove perforation during hip replacement arthroplasty. Methods. Gloves worn by surgical team members in 19 primary hip replacement arthroplasties were assessed. The study was of a single gloving system. All the used gloves were collected at the end of the surgery and assessed visually and by using water infla...

متن کامل

Glove perforation and contamination in primary total hip arthroplasty.

We conducted a randomised, controlled trial to determine whether changing gloves at specified intervals can reduce the incidence of glove perforation and contamination in total hip arthroplasty. A total of 50 patients were included in the study. In the study group (25 patients), gloves were changed at 20-minute intervals or prior to cementation. In the control group (25 patients), gloves were c...

متن کامل

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016