Retrospective Synthetic Focusing with Correlation Weighting for Very High Frame Rate Ultrasound
نویسنده
چکیده
The need of high frame-rate imaging has been triggered by the new applications of ultrasound imaging to transient elastography and real-time 3D ultrasound. Using plane wave excitation (PWE) is one of the methods to achieve very high frame-rate imaging since an image can be formed with a single insonification. However, due to the lack of transmit focusing, the image quality with PWE is lower compared with those using conventional focused transmission. To solve this problem, we propose a filter-retrieved transmit focusing (FRF) technique combined with cross-correlation weighting (FRF+CC weighting) for high frame-rate imaging with PWE. A restrospective focusing filter is designed to simultaneously minimize the predefined sidelobe energy associated with single PWE and the filter energy related to the signal-to-noise-ratio (SNR). This filter attempts to maintain the mainlobe signals and to reduce the sidelobe ones, which gives similar mainlobe signals and different sidelobes between the original PWE and the FRF baseband data. Normalized cross-correlation coefficient at zero lag is calculated to quantify the degree of similarity at each imaging point and used as a weighting matrix to the FRF baseband data to further suppress sidelobes, thus improving the filter-retrieved focusing quality. Keywords—retrospective synthetic focusing, high frame rate, correlation weighting.
منابع مشابه
Synthetic Aperture Ultrasound Image Reconstruction
In this paper real data was used to test the utility of synthetic aperture (SA) ultrasound imaging to overcome the limitation of conventional ultrasound image which include decreasing the frame rate and single transmit focusing. The images are reconstructed by using different types of transmission and used to test the effect of signal to noise ratio (SNR). The results show that increasing the n...
متن کاملSession: P2D
The synthetic aperture focusing technique (SAFT) has been previously employed to increase the penetration and to extend the depth of focus. This is particularly important in high frequency ultrasonic imaging because dynamic focusing using arrays is not yet possible. However, performance of the SAFT is limited due to its high sidelobes. In this paper, an adaptive weighting technique based on a f...
متن کاملEcho speckle imaging of blood particles with high-frame-rate echocardiography
Cardiac blood flow patterns such as the vortex flow pattern inside the left ventricle have been studied to provide new information for the diagnosis of the pumping function of the human heart. Complex blood flow is visualized by imaging echo speckles of blood particles because the speckle-like texture translates to the motion of blood particles. We proposed an imaging method for echo speckles o...
متن کاملSynthetic aperture ultrasound imaging.
The paper describes the use of synthetic aperture (SA) imaging in medical ultrasound. SA imaging is a radical break with today's commercial systems, where the image is acquired sequentially one image line at a time. This puts a strict limit on the frame rate and the possibility of acquiring a sufficient amount of data for high precision flow estimation. These constrictions can be lifted by empl...
متن کاملCompact Beamformer Design with High Frame Rate for Ultrasound Imaging
In medical field, two-dimension ultrasound images are widely used in clinical diagnosis. Beamformer is critical in determining the complexity and performance of an ultrasound imaging system. Different from traditional means implemented with separated chips, a compact beamformer with 64 effective channels in a single moderate Field Programmable Gate Array has been presented in this paper. The co...