Methods of fit testing hearing protectors , with representative field test data
نویسندگان
چکیده
Numerous published studies in the past 20 years clearly demonstrate that use of laboratory measurements to predict real-world attenuation for groups of workers, or even more problematically for individual workers, is fraught with inaccuracies. Thus, the ability to properly assign hearing protectors in critical high-noise environments or even for lower noise levels when one wishes to closely match attenuation to actual exposure, is questionable. Even if the laboratory data were representative of the actual group using the device, the individual variability is large enough that attempts at predicting one person’s performance from group data can easily err by up to 20 dB (Gauger & Berger 2004).
منابع مشابه
طراحی و ساخت آداپتور آزمون حفاظهای شنوایی
Introduction: To determine the effectiveness of hearing protective devices that lack the technical information are one of the major challenges of occupational health experts to judge the impact of this exposure on reducing the level of occupational exposure to noise. The aim of this study was to design a built a hearing test adapter and expriment it to determine the reduction rate of earmuffs a...
متن کاملAlternative field methods for measuring hearing protector performance.
In comparison with the mandatory noise reduction rating (NRR) testing of every hearing protector sold in the United States, real-world tests of hearing protector attenuation are scarce. This study evaluated data from three potential field-test methods as compared with the subject-fit data from Method B of ANSI S12.6-1997 for the E.A.R(R) Express trade mark Pod Plug trade mark. The new field-tes...
متن کاملIndividual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear
Background Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods Five available commercially earmuff protect...
متن کاملEstimating the Performance of Sound Restoration Hearing Protectors by Using the Speech Intelligibility Index
Despite advances in engineering noise controls and the use of administrative controls, miners are still dependent on hearing protection devices for prevention of noise-induced hearing loss. However, miners often raise concerns about the audibility of spoken communication when wearing conventional hearing protectors. Electronic technologies that selectively process and restore sounds from outsid...
متن کاملSound restoration hearing protection: Genesis of a standard test method
It is known that exposure to high sound pressure levels can lead to permanent hearing loss; however, many workers, in mining as well as other occupational sectors, frequently receive hazardous noise exposures. The National Institute for Occupational Safety and Health (NIOSH) recommends using a criterion level of 85 dB(A) for implementation of hearing loss prevention programs. But, despite engin...
متن کامل