Dynamic Modeling And Control of Single and Multi-Evaporator Subcritical Vapor Compression Systems
نویسندگان
چکیده
منابع مشابه
Modeling And Validation Of A Multi-Evaporator Vapor Compression Cycle Subject To Non-Uniform Loading In Transport Refrigeration Applications
This paper describes a multi-evaporator vapor compression model capable of simulating the dynamic behaviour of transport refrigeration systems. A discrete multi-zone control volume approach is utilised for modelling the condenser and evaporators. All other major refrigeration components including compressor, expansion valves, receiver, pressure-regulating valves are modeled using time-dependent...
متن کاملA Trajectory-based Bumpless Switching Control of Multi-Evaporator Air-Conditioning Systems
Multiple-evaporator/vapor compression cooling systems are used for air conditioning in multi-zone buildings with a refrigerant supplied to each individual zone-evaporator from a central compressor/condenser unit. Such systems, incorporating controlled electronic expansion valves associated to each evaporator and a variable-speed compressor, allow the overall system to be able to operate in diff...
متن کاملFuzzy Modeling and Identification of Vapor Compression Elements of Aif Conditioning System for Integrated Fuzzy Model
Conventional control techniques are not able to accomplish the stable cooling in vapor compression air conditioning system. This paper describes the fuzzy models of refrigerating compressor, expansion valve, evaporator and condenser as basic elements of vapor compression air conditioning system. Compressor speed, delivery pressure, refrigerant flow rate, valve opening area, pressure difference ...
متن کاملDynamical modeling and thermo-economic optimization of a cold room assisted vapor-compression refrigeration cycle
A cold room assisted vapor-compression refrigeration cycle is dynamically modeled in a year and optimized. Total annual cost (TACO) and coefficient of performance (COP) are selected as two objective functions. Both cold room and refrigeration cycle parameters are considered as design variables. Moreover, three working fluids included R22, R134a and R407c are examined. The optimum Pareto front r...
متن کاملMulti-objective optimization of compression refrigeration cycle of Unit 132 South Pars refineries
The purpose of this paper is multi-objective optimization of refrigeration cycle by optimization of all components of the cycle contains heat exchangers, air condenser, evaporator and super-heater. Studied refrigeration cycle is compression refrigeration cycle of unit 132 Third refineries in south pars that provide chilled water for cooling refinery equipment's. Cycle will be performed by t...
متن کامل