Single-breath test in lateral decubitus reflects function of single lungs grafted for emphysema.

نویسندگان

  • Alain Van Muylem
  • Pietro Scillia
  • Christiane Knoop
  • Manuel Paiva
  • Marc Estenne
چکیده

The slope of alveolar plateau for nitrogen derived from the single-breath test is useful to assess the function of bilateral lung grafts, but this technique is not applicable to patients with single-lung grafts due to the confounding influence of the native lung. We tested the hypothesis that the nitrogen slope measured in lateral decubitus with the graft in nondependent position may primarily reflect the distribution of ventilation in this lung. Fifteen patients with single-lung transplantation for emphysema, 10 healthy controls, and 7 patients with advanced emphysema performed single-breath washouts in right and left lateral decubitus; nitrogen slope was measured between 75 and 100% of expired volume. In 10 transplant recipients, the volume of each lung was measured in the two postures by computerized tomography. Nitrogen slope was unaffected by posture in normal controls and emphysema patients. On the other hand, nitrogen slope in transplant recipients was invariably smaller, with the graft in nondependent vs. in dependent position. Values of nitrogen slope with the graft in nondependent position were similar to those obtained in normal controls but significantly smaller than those obtained in emphysema patients. Computerized tomography studies in this position indicated that the volume expired below functional residual capacity was exclusively contributed by the graft. We conclude that, in patients with single-lung transplantation for emphysema, 1) measuring nitrogen slope in lateral decubitus allows to distinguish between the graft and the native lung, and 2) nitrogen slope obtained with the graft in nondependent position reflects ventilation distribution in this lung.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-breath test in lateral decubitus reflects function of single lungs grafted for interstitial lung disease.

After single-lung transplantation (SLT) for emphysema, heterogeneity of ventilation distribution in the graft can be assessed by measuring the slope of the alveolar plateau, computed from a single-breath test, performed in lateral decubitus with this lung in the nondependent position. We tested the validity of this technique in patients with SLT for interstitial lung diseases (ILD). Twelve pati...

متن کامل

Small airways obstruction syndrome.

STUDY OBJECTIVES To clarify the significance of a functional lung pattern characterized by a decreased vital capacity (VC) and an increased residual volume (RV), but with a normal FEV1/VC ratio. SETTING A university teaching hospital. SUBJECTS Patients with bronchial asthma, pulmonary emphysema, and small airways disease, and older subjects. MEASUREMENTS Measurements of static and dynamic...

متن کامل

Ventilation inhomogeneity in alpha1-antitrypsin-deficient emphysema.

The slope of phase III of the single-breath nitrogen wash-out test (sbN2-test) measures ventilation inhomogeneity and, in smokers, is strongly associated with small airways pathology. The present authors aimed to study ventilation inhomogeneity in emphysema related to type Z alpha1-antitrypsin (AAT) and to assess its relationship with indices of parenchymal damage and airways obstruction. A tot...

متن کامل

Evaluation of Pulmonary Function Test in Patients with Amyotrophic lateral sclerosis and its correlation with the symptoms of the disease

Introduction: Amyotrophic lateral sclerosis (ALS) is a neurogenic progressive disease that leads to muscle atrophy. The purpose of this study was to evaluate pulmonary function test (PFT) in patients with ALS and its correlation with ASL symptoms. Materials and Methods: This cross-sectional study was performed on 32 ALS patients at Ghaem Hospital, Mashhad...

متن کامل

Physiologic effects of the position of the body in experimental unilateral emphysema.

The functional residual capacity (FRC), static compliance (Cst) of the respiratory system, minute ventilation, and arterial blood gas levels were studied in the prone, the suprine, and the right and left lateral decubitus positions in dogs with papain-induced emphysema of the right lung alone and were compared with control values. The FRC and Cst of the respiratory system were significantly inc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 100 3  شماره 

صفحات  -

تاریخ انتشار 2006