Systolic blood pressure estimation using PPG and ECG during physical exercise.

نویسندگان

  • S Sun
  • R Bezemer
  • X Long
  • J Muehlsteff
  • R M Aarts
چکیده

In this work, a model to estimate systolic blood pressure (SBP) using photoplethysmography (PPG) and electrocardiography (ECG) is proposed. Data from 19 subjects doing a 40 min exercise was analyzed. Reference SBP was measured at the finger based on the volume-clamp principle. PPG signals were measured at the finger and forehead. After an initialization process for each subject at rest, the model estimated SBP every 30 s for the whole period of exercise. In order to build this model, 18 features were extracted from PPG signals by means of its waveform, first derivative, second derivative, and frequency spectrum. In addition, pulse arrival time (PAT) was derived as a feature from the combination of PPG and ECG. After evaluating four regression models, we chose multiple linear regression (MLR) to combine all derived features to estimate SBP. The contribution of each feature was quantified using its normalized weight in the MLR. To evaluate the performance of the model, we used a leave-one-subject-out cross validation. With the aim of exploring the potential of the model, we investigated the influences of the inclusion of PAT, regression models, measurement sites (finger and forehead), and posture change (lying, sitting, and standing). The results show that the inclusion of PAT reduced the standard deviation (SD) of the difference from 14.07 to 13.52 mmHg. There was no significant difference in the estimation performance between the model using finger- and forehead-derived PPG signals. Separate models are necessary for different postures. The optimized model using finger-derived PPG signals during physical exercise had a performance with a mean difference of 0.43 mmHg, an SD of difference of 13.52 mmHg, and median correlation coefficients of 0.86. Furthermore, we identified two groups of features that contributed more to SBP estimation compared to other features. One group consists of our proposed features depicting beat morphology. The other comprises existing features depicting the dicrotic notch. The present work demonstrates promising results of the SBP estimation model during physical exercise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvements in Indirect Blood Pressure Estimation via Electrocardiography and Photoplethysmography

Abstract—With the rapid adoption of wearable technology, a ubiquitous platform may exist for continuous cuff-less blood pressure monitoring. Devices that monitor photoplethysmography (PPG) and/or electrocardiography (ECG) signals may be capable of accurately estimating blood pressure. Previous work has demonstrated promising estimation techniques, but they remain infeasible for consumer adoptio...

متن کامل

An Estimation Technique using FFT for Heart Rate Derivedfrom PPG Signal

Heart rate (HR) observation by using photoplethysmography (PPG) signals during intense physical activity is a crucial task because of the fact that PPG signals are affected by the noise due to movement artifacts by the user's hand movements. This paper addresses the discriminating assessment of a novel encapsulation for wearable PPG sensor during the severe physical activity. In this work, we p...

متن کامل

The Effect of Eucalyptus Essence Inhalation on Pulmonary Function During One bout of a Submaximal exercise in Young Girls

Background: Respiratory function is very important for athletes and can have an impact on physical performance. Inhaling aromatic essential oils can also improve physical performance by influencing pulmonary function. Objective: Hence, the current study has been done with the purpose of investigating the effect of Eucalyptus essence inhalation on pulmonary function during one bout of a submaxi...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

Comparison of Systolic Blood Pressure Values Obtained by Photoplethysmography and by Korotkoff Sounds

In the current study, a non-invasive technique for systolic blood pressure (SBP) measurement based on the detection of photoplethysmographic (PPG) pulses during pressure-cuff deflation was compared to sphygmomanometry-the Korotkoff sounds technique. The PPG pulses disappear for cuff-pressures above the SBP value and reappear when the cuff-pressure decreases below the SBP value. One hundred and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 37 12  شماره 

صفحات  -

تاریخ انتشار 2016