ECG Artifact Removal from Surface EMG Signals by Combining Empirical Mode Decomposition and Independent Component Analysis
نویسندگان
چکیده
The electrocardiography (ECG) artifact in surface electromyography (sEMG) is a major source of noise influencing the analyses. Moreover, in many cases the sEMG signal is the only available signal, making this removal more complicated. We compare the performance of two recently described single channel blind source separation methods with the commonly used template subtraction method on both simulations and real-life data. These two methods decompose a single channel recording into a multichannel representation before applying independent component analysis to these multichannel data. The decomposition methods are the wavelet decomposition and ensemble empirical mode decomposition (EEMD). The EEMD based single channel technique shows better performance compared to template subtraction and the wavelet based alternative for both high and low signal-to-artifact ratio and for simulated and real-life data, but at the expense of a higher computational load. We conclude that the EEMD based method has its potential in eliminating spike-like artifacts in electrophysiological signals.
منابع مشابه
ECG Artifact Removal from Surface EMG Signal Using an Automated Method Based on Wavelet-ICA
This study aims at proposing an efficient method for automated electrocardiography (ECG) artifact removal from surface electromyography (EMG) signals recorded from upper trunk muscles. Wavelet transform is applied to the simulated data set of corrupted surface EMG signals to create multidimensional signal. Afterward, independent component analysis (ICA) is used to separate ECG artifact componen...
متن کاملRemoving ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique
Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...
متن کاملCorrigendum to: “Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique†published in J Biomed Phys Eng 2014; 4(1):31-38
متن کامل
Proposing Combined Approaches to Remove Ecg Artifacts from Surface Emg Signals
Electromyography (EMG) is a tool routinely used for a variety of applications in a very large breadth of disciplines. However, this signal is inevitably contaminated by various artifacts originated from different sources. Electrical activity of heart muscles, electrocardiogram (ECG), is one of sources which affects the EMG signals due to the proximity of the collection sites to the heart and ma...
متن کاملFastICA peel-off for ECG interference removal from surface EMG
BACKGROUND Multi-channel recording of surface electromyographyic (EMG) signals is very likely to be contaminated by electrocardiographic (ECG) interference, specifically when the surface electrode is placed on muscles close to the heart. METHODS A novel fast independent component analysis (FastICA) based peel-off method is presented to remove ECG interference contaminating multi-channel surfa...
متن کامل