High Throughput, Direct Analysis of Seawater using the Agilent 7800 ICP-MS with HMI for Aerosol Dilution
نویسندگان
چکیده
The Environment Agency (EA) is an executive nondepartmental public body that is sponsored by the UK government’s Department for Environment, Food and Rural Affairs (DEFRA). Part of EA’s remit is to safeguard the natural environment of England, protecting and improving the environment to create better places for people and wildlife. Similar Agencies perform equivalent functions in the other, devolved regions of the UK. The Agency also has a duty to manage and protect surface waters and groundwaters, including waters used for drinking water abstraction and aquaculture. This task involves the analysis of many varying water matrices. High Throughput, Direct Analysis of Seawater using the Agilent 7800 ICP-MS with HMI for Aerosol Dilution
منابع مشابه
Analysis of 10 nm Gold Nanoparticles using the Agilent 7800 ICP - MS
High sensitivity and low background noise are critical for the detection of small nanoparticles by ICP-MS. The signal generated by the ionization of a nanoparticle decreases as the cube root of the diameter. This means detection of very small particles, such as 10 nm Au particles (NIST 8011), requires ICP-MS instrumentation with significantly higher sensitivity than is required for the more typ...
متن کاملUsing qualifier ions to improve ICP-MS data quality for waste water analysis
Researchers at a commercial environmental laboratory have developed an effective method for validating high throughput multi-element data from high matrix waste water samples. The method used an Agilent 7700x ICP-MS with High Matrix Introduction (HMI)1 capability and third generation Collision Reaction Cell (CRC) operating in helium (He) mode. This simultaneously removes the polyatomic interfer...
متن کاملDirect Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS
Ammonium hydroxide (NH4OH) is a chemical used in the manufacture of semiconductor devices, and must therefore be analyzed for trace metal impurities. The direct analysis of undiluted (20%) NH4OH using ICP-MS is challenging because its high vapor pressure causes plasma instability. However, dilution of the samples would degrade detection limits, so the ability to directly analyze 20% NH4OH is im...
متن کاملDirect measurement of metallic impurities in 20% ammonium hydroxide by Agilent 7700s ICP-MS
Ammonium hydroxide (NH4OH) is a chemical used in the manufacture of semiconductor devices, and must therefore be analyzed for trace metal impurities. The direct analysis of undiluted (20%) NH4OH using ICP-MS is challenging, because its high vapor pressure causes plasma instability. However, dilution of the samples would degrade detection limits, so the ability to directly analyze 20% NH4OH is i...