SU-E-J-165: Development of a Low-Cost and Clinically Available Patient Intrafraction Motion Monitoring System.
نویسندگان
چکیده
PURPOSE We have developed a flexible system in order to monitor the intrafraction motion. The purpose of our study is to extend the monitoring system to clinically available system with low cost. METHODS Our system is composed of a standard web camera with a low-cost and 8x magnitude telescope, a personal computer with our in-house software and a specific marker box. The telescopic lens was attached with the web camera to extend more effective distance of the measurement in order to avoid patient's interference. The dynamic calibration algorithm was developed to take into account patient's rotation during treatment in order to measure the intrafraction motion more accurately. Tracking three markers simultaneously based on a template matching technique using parallel CPU computing was performed to measure the intrafraction motion with dynamic calibration. To evaluate our new system, a respiratory motion QA phantom with 10 mm-amplitude was used in order to measure the amplitudes under the different angles of web camera setting (0 to 50 degree, 5 degree step) using our system and Varian Real-Time Position Management Respiratory Gating (Varian-RPM) System. The results of our system were compared with the results of Varian-RPM System. RESULTS The result of the amplitudes measured by our system and Varian RPM-System are 10.2±0.3 mm and 10.3±0.1mm at the angle of 0 deg., respectively. The values of both systems were within the tolerance value of AAPM Task group 142. The results of the amplitude of our system and Varian-RPM system were 10.2±0.3mm and 10.4±0.1mm, respectively, while the angle was changed. Under the parallel CPU computing, the calculation time to measure the position of the marker was about 50msec including the latency. CONCLUSIONS Our proposed system could have clinically acceptable accuracies. The system would be contributed broadly to improve the treatment accuracy because of low-cost installation of it.
منابع مشابه
ارتباط میان دامنه حرکتی و انحنای لوردوتیک ستون فقرات در ناحیه کمری با کمردردهای غیراختصاصی
Aims and Background: Non-specific low back pain has direct impact on quality of life, active days at work and healthcare cost. The purpose of this investigation was to study the relationship between lumbar lordosis and lumbar range of motion with non-specific low back pain. Methods and Materials: 50 students of kharazmi University (mean age :24 years, mean weight: 75.72 kg, mean height :180.5 c...
متن کاملPatient specific methods for room‐mounted x‐ray imagers for monoscopic/stereoscopic prostate motion monitoring
PURPOSE To investigate the improvement of combined monoscopic/stereoscopic prostate motion monitoring with room-mounted dual x-ray systems by adopting patient specific methods. METHODS The linac couch was used as a motion stage to simulate 40 highly dynamic real patient prostate trajectories. For each trajectory, 40 s pretreatment and 120 s treatment periods were extracted to represent a typi...
متن کاملAssessment of planning target volume margins for intensity-modulated radiotherapy of the prostate gland: role of daily inter- and intrafraction motion.
PURPOSE To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. M...
متن کاملProstate Intrafraction Motion Assessed by Simultaneous Kv
PROSTATE INTRAFRACTION MOTION ASSESSED BY SIMULTANEOUS KV FLUOROSCOPY AT MV DELIVERY by JUSTUS D. ADAMSON August 2009 Co-Advisor: Dr. Qiuwen Wu Co-Advisor: Dr. Jay Burmeister Major: Medical Physics Degree: Doctor of Philosophy Purpose: To investigate the use of a gantry mounted kV imager for prostate intrafraction motion measurement during simultaneous dose delivery. Materials & Methods: We dev...
متن کاملDependence of intrafraction motion on fraction duration for pediatric patients with brain tumors
The purpose of this study was to quantify the intrafraction motion of pediatric patients with brain tumors during radiation therapy and investigate any correlation between motion, use of general anesthesia, and daily treatment duration. 100 pediatric patients with a mean age of 8.5 years (range: 1.0 to 17.8) were included in this prospective study. Forty-one patients required general anesthesia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 39 6Part8 شماره
صفحات -
تاریخ انتشار 2012