Bronchial vasodilatory response to ionic and nonionic contrast media.

نویسندگان

  • E M Baile
  • L Wang
  • L Verburgt
  • P D Paré
چکیده

It has recently been shown that bronchial arterial injection of conventional contrast medium causes a significant increase in bronchial blood flow (Qbr) and that this response is partially attenuated after infusion of N omega-nitro-L-arginine (L-NNA). However, the precise mechanism for this increase in Qbr is unknown. In this study we examined the effect of bronchial arterial injection of conventional ionic as well as nonionic contrast media. We measured Qbr in nine anesthetized, ventilated, open-chest sheep. Qbr was recorded before (baseline) and at the peak response to injection of 0.5 ml of either 0.9% saline (control; isosmolar with plasma), Omnipaque 300 (iohexol; nonionic), Conray 66 (sodium iothalamate; ionic), or 50% dextrose (viscous control). Measurements were made during a control period, after infusion of the alpha-agonist phenylephrine (5 x 10(-6) to 5 x 10(-7) M), and after bronchial arterial infusion of L-NNA (10(-2) M). The results were as follows: bronchial arterial injection of saline, Omnipaque, Conray, and dextrose caused an increase in Qbr (P < 0.05). During the control period, increases in peak Qbr on injection of saline, Omnipaque, Conray, and dextrose were 55 +/- 29, 112 +/- 62, 280 +/- 99, and 388 +/- 125% of baseline, respectively. Bronchial arterial infusion of L-NNA lowered baseline Qbr and partially attenuated the response to injection of saline, Omnipaque, and Conray (P < 0.05). Phenylephrine, in doses that decreased baseline Qbr to the same extent as did L-NNA, did not attenuate the bronchial vasodilation. There was a linear relationship between osmolality and the percentage increase in bronchial blood flow. We conclude that an osmolar stress is the trigger for the contrast-induced bronchial vasodilation and that the response is partially mediated by endothelial release of nitric oxide.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of contrast media on coronary vascular resistance: contrast-induced coronary vasodilation.

STUDY OBJECTIVES To determine if the vasodilatory response to the intracoronary injection of ionic and nonionic contrast media in intact pigs is dependent on nitric oxide (NO). The mechanisms responsible for inducing the increase in coronary blood flow in response to the intracoronary injection of contrast media during angiography are still not entirely understood. There is evidence to suggest ...

متن کامل

The impact of coronary artery disease on the coronary vasomotor response to nonionic contrast media.

BACKGROUND Coronary artery disease (CAD) alters the vasomotor response to a variety of pharmacological agents. We tested the hypothesis that CAD also has an impact on the coronary vasomotor response to radiologic contrast media. METHODS AND RESULTS We performed quantitative coronary angiography in 42 patients without angiographic evidence of CAD and 38 patients with CAD in the left coronary a...

متن کامل

Ionic versus nonionic paramagnetic contrast media in differentiating between scar and herniated disk.

PURPOSE To compare the MR contrast enhancement produced by ionic and nonionic paramagnetic contrast media in herniated disk fragments with that in epidural scar tissue. METHODS A recurrent herniated disk was modeled in canines by using laminectomy to place a fragment of disk cartilage in the epidural space. The dogs were studied 88 and 90 days after laminectomy with MR imaging enhanced with a...

متن کامل

Ionic versus nonionic paramagnetic contrast media in differentiating between postoperative scar and recurrent disk.

BACKGROUND AND PURPOSE In theory, ionic solutes diffuse more slowly in cartilage than do nonionic solutes. We tested the hypothesis that the contrast ratio between scar and recurrent disk fragment on MR images is greater after IV administration of an ionic rather than a nonionic contrast medium when a clinical dose is used. METHODS Twenty patients who had recurrent lumbar disk herniation were...

متن کامل

Contrast between scar and recurrent herniated disk on contrast-enhanced MR images.

BACKGROUND AND PURPOSE Ionic solutes diffuse more slowly in cartilage than do nonionic ones. The purpose of this study was to test the hypothesis that the contrast between scar and recurrent herniated disk fragment on MR images is greater after the IV administration of an ionic rather than a nonionic contrast medium. METHODS Patients who had undergone previous laminectomy and who had MR imagi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 1997