Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.
نویسندگان
چکیده
Novel polymer-free drug-eluting stents have been developed to reduce polymer-related adverse events. However, neointimal coverage after polymer-free DES implantation is unclear and validation between optical coherence tomography (OCT) and histology is required. Sixteen polymer-free sirolimus-eluting stents were randomly implanted into coronary arteries of 8 normal swine. OCT and histological measurement were conducted at 3 or 6 months after stent placement. For quantitative measures, lumen area, stent area, neointimal area and neointimal thickness were validated in every single OCT and histology matched cross-section. Moreover, for qualitative analysis, OCT signal patterns of neointimal tissue were classified as homogeneous, layered and heterogeneous patterns based on optical intensity and backscatter pattern and peri-strut inflammation was also determined by histology. In total, 70 OCT and histology matched cross-sections were analyzed. At quantitative analysis, good correlations and agreements were found in the measurement of lumen area (ICC = 0.67, P<0.001), neointimal area (ICC = 0.89, P<0.001) and neointimal thickness (ICC = 0.94, P<0.001) except for stent area (ICC 0.19, P = 0.13) between OCT and histology. At qualitative analysis, lymphocyte infiltrations of peri-strut were more frequently seen in heterogeneous sections than in homogeneous sections (10/14 sections, 71.4% vs. 12/50 sections, 24%; P = 0.003). In conclusion, OCT has proper correlation and agreement with histology in assessment of neointimal formation and heterogeneous neointima assessed by OCT may also be associated with peri-strut inflammation detected in histology after polymer-free sirolimus-eluting stents implantation, supporting the use of OCT to evaluate neointimal coverage after polymer-free stent implantation in clinical practice.
منابع مشابه
Vascular response profiles following a nano polymer-free sirolimus-eluting stent implantation assessed by optical coherence tomography in a porcine model
Optical coherence tomography (OCT) is a high resolution imaging modality and has been considered as the ideal tool for the evaluation of neointimal tissue and vascular responses following stent implantation. However, vascular response profiles following the implantation of a novel nano polymer-free sirolimus-eluting stent (SES) assessed by OCT has not been fully investigated. Therefore, the aim...
متن کاملSerial assessment by optical coherence tomography of early and late vascular responses after implantation of an absorbable-coating Sirolimus-Eluting stent (from the first-in-human DESSOLVE I trial).
The initial enthusiasm caused by the potent antirestenotic effect of early generation drug-eluting stents was recently plagued by concerns regarding their safety profile. Investigators worldwide were stimulated, therefore, to seek for improvement in drug-eluting stent technology, such as eliminating their permanent polymer blamed for vascular inflammation and delayed healing. Optical coherence ...
متن کاملA randomized, open-label clinical trial using optical coherence tomography to compare two sirolimus-eluting stents, one with a biodegradable polymer and the other with a permanent polymer.
Intimal hyperplasia appears to differ after implanting a drug-eluting stent (DES) with a biodegradable or a permanent polymer. The aim of the present study was to compare biodegradable with permanent polymer DES, since the available data are limited. One hundred patients with de novo coronary artery stenosis were included in this study. The patients were classified into 2 groups: DES with a bio...
متن کاملLate vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: serial observations by intracoronary optical coherence tomography.
BACKGROUND Late vascular responses after implantation of drug-eluting stents may play a key role in steadily increasing occurrence of very late stent thrombosis have not yet been fully investigated in human beings. METHODS AND RESULTS Serial optical coherence tomography observations at 2 and 4 years were collected for 17 patients treated with 21 sirolimus-eluting stents. Corresponding 376 cro...
متن کاملOptical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents
OBJECTIVE To evaluate the vascular response at 9 months after zotarolimus-eluting stent (ZES; Endeavor) implantation using optical coherence tomography (OCT). These findings were compared with those after implantation of a sirolimus-eluting stent (SES; Cypher Select). DESIGN Cross-sectional observational study with prospective OCT registry. SETTING Nine months after ZES or SES implantation....
متن کاملذخیره در منابع من