Concentrations and Size Distributions of Airborne Particulate Matter and Bacteria in an Experimental Aviary Laying-Hen Housing System

نویسندگان

  • W. Zheng
  • Yang Zhao
  • Hongwei Xin
  • Baoming Li
  • Richard S. Gates
چکیده

High levels of airborne particulate matter (PM) and bacteria may exist in animal housing, which can be detrimental to the health of animals and workers. The sizes of these bioaerosols determine their aerialtransport behaviors and depositions in the respiratory tracts of animals and humans. However, little is known regarding the size distribution of airborne PM and bacteria in livestock houses, especially alternative animal housing systems that aim to enhance animal welfare, such as aviary hen-housing systems. The study reported here was therefore conducted to characterize the concentrations (both in count and in mass) and size distributions of airborne bacteria (in count) and PM (both in count and in mass) in a pilot-scale welfareoriented aviary laying-hen setting. Thirty-four laying hens were kept in the environmentally-controlled aviary setting (L × W × H = 2.2 × 2.3 × 2.4 m) for 3 months. The hens were given a 16L:8D photoperiod (lights on at 6:00h and off at 22:00h); and access to the litter floor from 12:00h to 22:00h daily. Airborne bacteria and PM were simultaneously sampled for 15 min at 1.5 m height above the litter floor every fourth day at 5:45h, 9:45h, 13:45h,17:45h, and 21:45h. Concentrations of airborne bacteria at six size ranges (0.65-1.1 Âμm, 1.1-2.1 Âμm, 2.1-3.3 Âμm, 3.3-4.7 Âμm, 4.7-7.1 Âμm, and >7.1 Âμm) and the PM concentrations (0.5-20 Âμm) were determined. The daily mean (±SD) concentrations of PM count, PM mass and total bacterial concentration were, respectively, 1.70 (± 0.66) ×107 particles m-3, 1.12 (± 0.47) mg m-3 and 3.39 (± 2.38) ×105 CFU m-3. Concentrations of PM and total bacteria during the litteraccess period (12:00h-22:00h) were significantly higher than those during the rest of the day when the hens were off the floor (P <0.05). Median diameters for the PM count and mass were, respectively, 2.11 Âμm and 7.45 Âμm. PM <10 Âμm accounted for more than 95% of the total PM count, whereas PM >2.5 Âμm accounted for more than 90% of the total PM mass. The majority (>95%) of the airborne bacteria were contained in particles >3.3 Âμm. Airborne bacteria count was positively related to PM mass concentration (P <0.05) with a slope of 3.84(± 2.70) ×105 CFU mg-1 PM. Results of the study are useful for improving understanding of transport behaviors of aerosols in the aviary hen setting, assessing potential respiratory risks to humans and animals, and exploring mitigation techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Airborne Particulate Matter and Bacteria Reduction from Spraying Slightly Acidic Electrolyzed Water in an Experimental Aviary Laying-Hen Housing System

Compared to conventional cage systems for laying hens, aviary housing systems generally have much higher concentrations of airborne dust and bacteria due to generation of bioaerosols by the hens from their litter access. Hence solutions to reduce these health-degrading agents are required to safeguard the indoor environment in such systems. Spraying slightly acidic electrolyzed water (SAEW) has...

متن کامل

Ammonia, Greenhouse Gas, and Particulate Matter Concentrations and Emissions of Aviary Layer Houses in the Midwestern USA

There has been an increased interest in alternative housing for laying hens in certain parts of the world, including the United States. Associated with the movement are many questions to be addressed concerning sustainability of such systems. This study continually quantifies concentrations and emissions of ammonia (NH3), carbon dioxide (CO2), methane (CH4), and particulate matters (PM10 and PM...

متن کامل

Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality

To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a...

متن کامل

Lung toxicity in mice of airborne particulate matter from a modern layer hen facility containing Proposition 2-compliant animal caging.

Proposition 2, which requires that egg-laying hens be confined only in ways that allow these animals to lie down, stand up, fully extend their limbs and turn around freely, was passed by the voters of California in 2008. These new housing requirements were introduced in the USA and European Union without considering the potential impact of changes in layer hen housing on the health of poultry w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017