SU-E-T-537: Photon Beam Modeling and Verification of Collapsed Cone Convolution Algorithm for Dose Calculation in a Radiation Treatment Planning System.
نویسندگان
چکیده
PURPOSE The aim of this study is to evaluate the accuracy the collapsed cone convolution (CCC) algorithm for dose calculation in a radiation treatment planning system (TPS). METHODS We modeled various photon beams for various setup conditions in a radiation treatment planning system (CorePLANTM, Seoul C&J, Korea). The beam models were generated at various set-up conditions such as open beam or wedged beam, 6 MV or 15 MV beam and field sizes from 4×4 cm2 to 40 × 40 cm2 . Each beam model was optimized by spectrum modeling from measured percent depth dose (PDD) data, dose profile modeling from a measured profile at a specific depth (10 cm) data. Dose calculation was performed using conventional CCC algorithm. All measured data were acquired from a Clinac 21EX (Varian Medical System, Palo Alto, CA, USA) linear accelerator with the setting of SSD = 100 cm. All calculated PDD and dose profiles at various depths from generated beam models were compared to the measured data. RESULTS Calculated dose data from each beam model showed good agreements within 2% of difference to the measured PDD and within 3% dose profiles at various depths. Some regions such as penumbra region at 20 × 20 cm2 field size and horn region at wedge field showed dose discrepancies over 3%. The results of PDD at all situations showed well agreement with measured data under the 10×10 cm2 field size. For wedged cases, however, under the 5 cm depths, some inconsistency at penumbra region were appeared. CONCLUSIONS In this study, we verified the accuracy of CCC algorithm in the TPS. Calculated results by our implemented algorithm was well satisfied with measured dose at small field size (〈20 7 times; 20 cm2 ). Our next study will perform to compensate theses inconsistencies.
منابع مشابه
Calculation of absorbed dose in lung tissue equivalent and compared it with prediction of a treatment planning system using Collapsed Cone Convolution algorithm
External radiotherapy is used for treatment of various types of cancers. Due to the impossibility of measuring the absorbed dose delivered to different organs during irradiation, treatment planning systems (TPSs) have been utilized for calculation of absorbed dose before a radiotherapy procedure. Thus, the accuracy and precession of the TPS is essential.The aim of this study is investigation of...
متن کاملDosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area
Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...
متن کاملDose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code
Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...
متن کاملEvaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry
Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...
متن کاملComparison of radiotherapy techniques to reduce hematologic toxicity in whole pelvic radiation therapy
Introduction: Concurrent chemoradiotherapy (CRT) is a standard treatment method for patients with carcinoma of cervix. Despite admirable therapeutic results, acute hematologic toxicity (HT) is common with this regimen. Many studies evaluate the relationship between the bone marrow dosimetric parameters and the severity of HT and result shown that the low dose of bone marrow wou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part18 شماره
صفحات -
تاریخ انتشار 2012