Clinical performance of KeraSoft® IC in irregular corneas
نویسندگان
چکیده
PURPOSE This study evaluated the clinical performance of KeraSoft(®) IC (KIC) soft contact lenses in subjects with irregular corneas. PATIENTS AND METHODS This was a 12-month, prospective, open-label, observational study, which enrolled 43 subjects who were 18 years of age or older with irregular corneas. Subjects were fit according to the KIC Fitting Manual (kerasoftic.com). After achieving best fit according to the fitting manual, lenses were assessed for comfort, vision, centration, rotation, and movement. Subjects were instructed to wear their lenses between 8 and 16 hours each day. Assessments at the exit visit included logMAR visual acuity with high and low contrast, spherocylindrical overrefraction, slit-lamp findings, adverse events, and subjective outcomes. RESULTS The average base curve was 8.17±0.32 mm (n=70 eyes), and the average diameter dispensed was 14.53±0.12 mm (n=70 eyes). From the baseline to 12 months, there was statistically significant improvement in logMAR visual acuity with high contrast (P=0.038), but no significant difference in low-contrast visual acuity was observed (P>0.05). Slit-lamp findings were ≤ grade 1 for the majority of subjects (89%). Two nonserious adverse events were reported for two of the 84 enrolled eyes (two subjects). At 12 months, subjects reported improvements from habitual baseline for comfort and vision, both upon insertion and just before removal of lenses. CONCLUSION Clinical outcomes at 12 months showed good visual, safety, and subjective outcomes for subjects with corneal irregularities who wore KeraSoft(®) IC soft contact lenses.
منابع مشابه
Response to "Kerasoft IC compared to Rose-K in the management of corneal ectasias".
PURPOSE To determine the efficacy of the KeraSoft(®) IC (KIC) (Ultravision International Limited, Bedfordshire, UK), a silicone hydrogel contact lens, for the optical management of non-surgical corneal ectasias and to compare it with the Rose-K 2 RGP contact lens. METHODS In a retrospective study ninety-four eyes fitted with KIC (group A) were compared with seventy-seven eyes fitted with Rose...
متن کاملHydro cone lens visual performance and impact on quality of life in irregular corneas.
The aim of this study is to evaluate the visual performance (efficiency) of HydroCone (Toris K) soft silicon hydrogel lenses in patients with irregular corneas.
متن کاملComparison of Efficacy and Safety of Two Different Enoxaparin Products in Prevention of Venous Thromboembolism Following Major Obstetric-gynecological Surgeries: An Open-label Randomized Clinical Trial
Venous thromboembolism (VTE) occurs in about 5 percent of patients undergoing major abdominal surgeries. Prophylaxis of VTE is recommended using unfractionated heparin (UF) or low molecular weight heparin (LMWH) in high-risk patients. In spite of advantages and confirmed cost-effectiveness of LMWH, high costs of enoxaparin branded preparations limit its use. We aimed to compare the efficacy and...
متن کاملComparison of Efficacy and Safety of Two Different Enoxaparin Products in Prevention of Venous Thromboembolism Following Major Obstetric-gynecological Surgeries: An Open-label Randomized Clinical Trial
Venous thromboembolism (VTE) occurs in about 5 percent of patients undergoing major abdominal surgeries. Prophylaxis of VTE is recommended using unfractionated heparin (UF) or low molecular weight heparin (LMWH) in high-risk patients. In spite of advantages and confirmed cost-effectiveness of LMWH, high costs of enoxaparin branded preparations limit its use. We aimed to compare the efficacy and...
متن کاملCapillarys 3 Octa®: Analytical Performance Assessment for HbA1c Quantification
Objective: Determination of HbA1c level is a precious indicator for therapeutic follow-up of patients with type 1 or type 2 diabetes. Our study aimed to evaluate the analytical characteristics of Capillarys 3 Octa® HbA1c measurement by capillary electrophoresis. Materials and Methods: Our study involved 265 venous whole blood specimens repeatability, intermediate fidelity, accuracy, linearity,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2015