Particle-size and radiochemical purity evaluations of filtered 99mTc-sulfur colloid prepared with different heating times.

نویسندگان

  • Maggie M Michenfelder
  • Lucas J Bartlett
  • Douglas W Mahoney
  • Thomas J Herold
  • Joseph C Hung
چکیده

UNLABELLED Sentinel node lymphoscintigraphy using colloidal particles has become common practice at many institutions. The ideal particle size for colloids such as filtered (99m)Tc-sulfur colloid ((99m)Tc-FSC) in sentinel node studies is 15-100 nm. It is reported that the use of a reduced heating time during the reconstitution process results in an increased number of smaller particles (<30 nm). However, it is unclear whether these smaller particles (>15 nm) would be of benefit in sentinel node studies. This study sought to better define particle size by using electron microscopy, as well as to evaluate the radiochemical purity (RCP) of (99m)Tc-FSC at various time points after filtration. METHODS One group of (99m)Tc-sulfur colloid ((99m)Tc-SC) preparations was reconstituted using the standard heating time of 5 min, and another group was prepared using a reduced heating time of 3 min. The (99m)Tc-SC preparations were passed through a 0.2-μm filter, and retained filter activity was measured. RCP values were collected at 0, 1, 3, and 6 h after filtration, and the particle sizes were measured at 0 and 6 h after filtration. RESULTS Average RCP values (± SD) for (99m)Tc-FSC with 5-min heating were 98.4% ± 3.0% and 98.3% ± 1.8% for 0 h and 6 h, respectively (n = 6). Average RCP values for (99m)Tc-FSC with 3-min heating were 98.4% ± 4.1% and 96.9% ± 3.1% for 0 h and 6 h, respectively (n = 6). Electron microscopy data showed that median particle sizes for the 3-min heating at 0 and 6 h were 24 and 35 nm, respectively. Median particle sizes for the 5-min heating at 0 and 6 h were 29 and 27 nm, respectively. The proportion of particles within the ideal range for sentinel node lymphoscintigraphy was similar between the heating methods (91.1% for 3-min heating at 0 h and 88.8% for 5-min heating at 0 h, P = 0.1851). CONCLUSION Our results indicate that although there are slight significant differences in RCP value, particle size, and particle number for (99m)Tc-FSC prepared using either a standard or a reduced heating time, both methods produce particles within the optimum range for sentinel node studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of zeta-potential and particle size of technetium 99mTc-sulfur colloid subsequent to the addition of lidocaine and sodium bicarbonate.

UNLABELLED The use of (99m)Tc-sulfur colloid lymphoscintigraphy for the determination of lymph flow patterns from a tumor site and localization of the sentinel node has been widely adopted. However, the effects of multiple injections of the radiopharmaceutical can range from mild discomfort to pain. pH-adjusted lidocaine HCl coadministered with (99m)Tc-sulfur colloid presents a risk of introduc...

متن کامل

Production of 99mTc-Antimony Sulfide Colloid for lymphoscintigraphy [Persian]

Introduction: The lymphatic system provides one of the main paths for the spread (Metastasis) of cancer from one part of body to another. Hodgkin’s diseases, lymphocytic leukemia, various metastatic disease and many lymph node disorders can be assessed by lymphoscintigraphy. Radionuclide lymphoscintigraphy has been used for many years to define lymphatic drainage of melanoma. The most com...

متن کامل

Microwave Preparation of Technetium-99m Sulfur Colloid

Technetium-99m sulfur colloid ( mTc-SC) has been useful in reticuloendothelial imaging, and in particular in liver/spleen and more recently bone marrow scintigraphy. Technetium99m SC can also be employed to localize acute gastrointestinal bleeding and has been used in lung ventilation studies. The standard radiolabeling method requires a heating period in a boiling water bath. A comparison of a...

متن کامل

Technetium-99m radiopharmaceutical preparation problems: 12 years of experience.

OBJECTIVE Chemical reactions involved in preparing 99mTc radiopharmaceuticals occasionally result in products of substandard purity. A retrospective examination of preparation problems that occurred in the author's institution was conducted to better define the incidence, recognize patterns and identify causes of substandard 99mTc radiopharmaceutical products. METHODS All 99mTc radiopharmaceu...

متن کامل

Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals.

The influence of effective room temperature on the radiochemical purity of 99mTc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the 99mTc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the wo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 2014