A Linear Dose-Response Curve at the Motor Endplate

نویسنده

  • Lesley Harrington
چکیده

The motor endplate of frog sartorius muscle was voltage clamped and the peak current to different concentrations of acetylcholine and carbachol applied in the perfusing fluid was measured. Perfusing fluid was hypertonic in order to suppress contractions. Current responses were smooth and reached a peak value within 2-5 s. The dose-response curve was usually linear even with concentrations of 10(-2) M acetylcholine, indicating that the conductance change was probably proportional to the concentration of acetylcholine or carbachol. With high concentrations nonlinearity sometimes appeared but in these cases the fast onset of desensitization appeared to be preventing the current response from reaching its expected peak amplitude. When the depolarization produced by acetylcholine in a non-voltage-clamped endplate was measured the dose-response curve was hyperbolic. This relationship was imposed by the electrical properties of the endplate membrane and its surrounding sarcolemma, and could be predicted if the input resistance of the fiber was known. Experiments were also done on slow muscle fibers. Depolarizing analogues of acetylcholine had similar effects to acetylcholine. d-Tubocurarine reduced the proportionality constant between concentration of acetylcholine and conductance change, and this resulted in a parallel shift of the log-concentration depolarization curve. A linear dose-response curve was unexpected within the context of current theories of drug action.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biological Dose Assessment by Chemical Induction of Premature Chromosome Condensation

Dose assessment of radiation victims is a key element in medical management of radiation accidents. At high radiation doses (> 6 Gy), dicentric assay lose its efficiency and premature chromosome condensation (PCC) assay was proposed to overcome the restrictions of dicentric assay. It was shown that PCC ring is more suitable and simpler than dicentric for biodosimetry in high radiation doses. In...

متن کامل

Determination of dose-response relationship in cultured human lymphocytes for biological dosimetry

Background: Lymphocyte-dicentric assay is the most generally accepted method for biological dosimetry of overexposed individuals. In this study, the frequency of unstable chromosome aberration in blood lymphocytes was used to estimate radiation dose received by individuals. Evaluation of dose using a calibration curve produced elsewhere may have a significant uncertainty therefore, experiments ...

متن کامل

Construction of a dose – response curve by induction of premature chromosome condensation for biological dosimetry

Premature Chromosome Condensation (PCC) appears to have a possible utility for biological dosimetry purposes. The PCC technique may be adapted for cases of suspicion of overexposure where sampling is performed at least one day after an accident. For this purpose, human blood samples were exposed in vitro to 60Co up to 10 Gy and the PCC technique was performed immediately after irradiation. Anal...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

Retrospective dosimetry using fingernail in nuclear industries: A review paper

Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of General Physiology

دوره 62  شماره 

صفحات  -

تاریخ انتشار 1973