Effect of different incision sites of phacoemulsification on trabeculectomy bleb function: prospective case-control study

نویسندگان

  • Mohamed Anbar
  • Hatem Ammar
چکیده

BACKGROUND The aim of this study was to compare superior and temporal clear corneal incisions of uneventful phacoemulsification and in-the-bag intraocular lens implantation on intraocular pressure control and the bleb morphology in eyes that have undergone previous successful trabeculectomy. METHODS In this Prospective case-control study, a total of 100 eyes of 100 patients previously undergone trabeculectomy without antimetabolites, divided into two groups. Group A (temporal group) including 50 patients underwent phacoemulsification with a temporal corneal incision and group B (superior group) including 50 patients underwent phacoemulsification with a superior corneal incision. Comparisons between the two groups were performed after one year of follow-up regarding Intraocular pressure changes, bleb morphology score using the Wuerzburg bleb classification score and any added glaucoma medications. RESULTS At the last visit, the mean intraocular pressure for the temporal group was 17.55 ± 1.47 (p = 0.51) and for the superior group was 16.90 ± 1.71 (p = 0.85); the difference between the two groups was insignificant (p = 0.21). Regarding the bleb morphology, the mean bleb morphology score in the temporal group was 10.50 ± 0.95 (p = 0.19) and for the superior group was 10.20 ± 1.06 (p = 0.01).There was an insignificant difference in the bleb grading morphology regarding both groups (p = 0.35). CONCLUSION Our study demonstrates that phacoemulsification whether done with a clear temporal or clear superior wound, does not affect intraocular pressure, bleb morphology or function after one year of follow-up in eyes following previous successful trabeculectomy. Furthermore, cataract surgery may be performed safely in eyes with functioning filtering blebs. TRIAL REGISTRATION ISRCTN91835217 'retrospectively registered' Date Of registration 6/6/2017.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deterioration of filtering bleb morphology and function after phacoemulsification

BACKGROUND Trabeculectomy remains the most efficient method of lowering he IOP applied for the treatment of glaucoma refractory to pharmacological treatment. Cataract is concerned as the most frequent late complication of trabeculectomy. The aim of the study was to analyse the effect of phacoemulsification with posterior chamber lens implantation on the morphology and function of filtering bleb...

متن کامل

Current Status of Mitomycin C-Augmented Trabeculectomy in Japan Based on Collaborative Bleb-Related Infection Incidence and Treatment Study

Purpose: To investigate the current status and demographics of patients who underwent mitomycin C-augmented trabeculectomy (MMC-trabeculectomy) in Japan using data from the Collaborative Bleb-related Infection Incidence and Treatment Study. Subjects and Methods: Out of 1,249 patients (1,249 eyes), we selected patients who underwent trabeculectomy alone or phacotrabeculectomy using MMC. Age at t...

متن کامل

The effect of phacoemulsification on late bleb failure or intraocular pressure in patients with glaucoma: a systematic review

The purpose of our systematic review is to document the adverse events that follow phacoemulsification in eyes with trabeculectomy due to glaucoma and to determine whether phacoemulsification jeopardizes the survival of the trabeculectomy. Our research was based on English- and non-English-language articles obtained using the Medline, Embase, Web of Science and Scopus databases. Additional stud...

متن کامل

An unusual case of posttrabeculectomy conjunctival granuloma

We report an unusual case of granulomatous inflammation that presented adjacent to bleb 3 weeks postoperatively after combined phacoemulsification and trabeculectomy surgery with mitomycin-C due to retained microfragments of methyl cellulose sponge. The commonly used antimetabolite delivery devices are made of cellulose. Methyl cellulose sponges are friable, and they are likely to leave behind ...

متن کامل

Comparison of Small Incision Trabeculectomy (Minitrab-clear Corneal) with Conventional Trabeculectomy in Primary Open Angle Glaucoma

Introduction: Primary open angle glaucoma is a symptom complex wherein there is damage to the optic nerve head with characteristic morphological and functional alterations in Optic Nerve Head (ONH). Aim: To compare the recent surgical approach minitrab with conventional trabeculectomy with reference to post-operative success. Materials and Methods: This prospective study was done in Theni Medic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017