Regular serial refraction was used to determine the rate of stabilisation of refraction following routine extracapsular cataract surgery in 85 eyes. Patients were divided into four groups depending on wound closure technique: limbal section closed by interrupted 8-0 virgin silk, 9-0 polydioxanone or 10-0 nylon sutures, and corneal section closed by continuous 10-0 nylon suture. Stabilisation of refraction, sufficient to prescribe satisfactory glasses, occurred at three months except in the interrupted 10-0 nylon group, when stabilisation was delayed to between four and five months. The factors affecting stabilisation and the causes of the differences observed are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stabilisation of refraction following cataract surgery.

Refraction was performed at frequent, regular intervals for six months following routine intracapsular cataract extraction. Patients were divided into two groups, those whose limbal sections were closed with 8-0 virgin silk or with 9-0 nylon. The stabilisation of refraction was observed, and the most suitable time to prescribe 'first glasses' was estimated retrospectively. In the silk group thi...

متن کامل

Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation

The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...

متن کامل

Predictability of refraction following immediate sequential bilateral cataract surgery (ISBCS) performed under general anaesthesia

BACKGROUND To evaluate the predictability of refraction following immediate sequential bilateral cataract surgery (ISBCS) performed under general anaesthesia. METHODS This is a retrospective review of all ISBCS performed at Kantonsspital Winterthur, Switzerland, between April 2000 and September 2013. The case notes of 250 patients were reviewed. Patients having full refraction reported (110 p...

متن کامل

Objective autorefraction in posterior chamber pseudophakia.

Automated refraction with the Canon RK-1 Autoref keratometer was evaluated in 110 eyes (110 patients) six to eight weeks after they had undergone extracapsular cataract extraction with posterior chamber intraocular lens implantation and achieved a best corrected visual acuity of at least 6/12. Autorefraction readings were obtained in 100 (91%) of these eyes. The agreement between autorefraction...

متن کامل

Accuracy of routine intraocular lens power calculation in a district general hospital.

To assess the accuracy of routine preoperative biometry we reviewed all cases of extracapsular cataract extraction with posterior chamber implant performed at Queen Alexandra Hospital in 1985. Of 471 eyes included in the survey 67.9% were within 1.0 D of the expected refraction and 90.7% within 2.0 D. Factors influencing accuracy are discussed. The necessity of routine preoperative biometry is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 74 8  شماره 

صفحات  -

تاریخ انتشار 1990