Direct Current Measurements in Cochlear Implants: An ill vivo

نویسندگان

  • Christie Q. Huang
  • Paul M. Carter
  • Robert K. Shepherd
  • Peter M. Seligman
  • Bruce Tabor
  • Graeme M. Clark
چکیده

Direct current (DC) was measured both in vivo and in vitro in cochlear implant electrodes with stimulation at moderate to high pulse rates in monopolar and bipolar modes. In vivo DC was approximately 2-3 times higher than that measured in vitro. In vivo DC levels were <100 nA even at very high rates, although DC levels increased as a function of stimulus rate and charge intensity. DC levels were lower: in the monopolar than in the bipolar stimulation condition. Stimulation with a monopolar capacitively coupled extracochlear electrode showed even lower DC levels in the intracochlear .electrodes. Our results indicated that the Nucleus electrode shorting system is able to maintain a low level of DC during very high rate stimulation for both monopolar and bipolar modes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Characterization of an Eis-based Method for Low- Invasive Diagnosis of Prosthesis Osseointegration

A digital measurement method for lowinvasive clinical diagnosis of metallic prosthesis osseointegration was proposed. Electrical impedance spectroscopy is exploited to characterize the quality of the interface bone-prosthesis tissue. In this paper, in vitro and in vivo experimental results of the application of the proposed method to the evaluation of osseointegration of metallic implants used ...

متن کامل

Optoacoustic effect is responsible for laser-induced cochlear responses

Optical stimulation of the cochlea with laser light has been suggested as an alternative to conventional treatment of sensorineural hearing loss with cochlear implants. The underlying mechanisms are controversially discussed: The stimulation can either be based on a direct excitation of neurons, or it is a result of an optoacoustic pressure wave acting on the basilar membrane. Animal studies co...

متن کامل

Direct Current Measurements in Cochlear Implants: An in Vivo and in Vitro Study - Bioelectromagnetism, 1998. Proceedings of the 2nd International Conference on

n of neural tissue involves the to tissue via electrodes. The ionic current takes place tissue interface by electrochemical a charge-balanced biphasic current mall amount of charge immediately following f the slow kinetics of the that store charge on the o methods of charge neural prostheses: i) ; ii) electrode shorting [2]. between the stimulator and any long-term residual charge. significant ...

متن کامل

Comparison of Auditory Perception in Cochlear Implanted Children with and without Additional Disabilities

Background: The number of children with cochlear implants who have other difficulties such as attention deficiency and cerebral palsy has increased dramatically. Despite the need for information on the results of cochlear implantation in this group, the available literature is extremely limited. We, therefore, sought to compare the levels of auditory perception in children with cochlear implant...

متن کامل

Speech Perception in Children with Cochlear Implants

Cochlear implants provide access to the speech signal in children with hearing loss that often cannot benefit from acoustic hearing aids. However, despite the numerous positive results in pediatric cochlear implantation, published data still indicated a wide range of performance among implant recipients. Hence, a need to study the possible variables that can affect performance, could account fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009