Reliability of fetal anthropometry by ultrasound.
نویسندگان
چکیده
The increasing importance of ultrasound in obstetrical practice requires a sound knowledge of the technique and of the reproducibility and accuracy of the measurements. In most obstetrical clinics, scanning are not always performed by the same technician and therefore the lack of Information about the errors in measurement of the different observers or of one observer may lead to inaccurate procedures. In this paper, the errors made by one observer in two consecutive scannings (intra-observer errors) and the differences among observers are determined, äs well äs the accuracy of the echograph for measuring fetal structures.
منابع مشابه
Study of Diagnosis of Pregnancy and Fetal Development by 2D Ultrasound in Markhoz Goat
Objective- The aim of this study was to obtain first time diagnosis of pregnancy and study of fetal development in different times of pregnancy period. Design- ِDescriptive study. Animals- 8 pregnant Markhoz goats. Procedure- 2D ultrasound was performed from day 25 to 130 of gestation, twice in week from day 25 to 70 and once in week from day 70 to 130 of gestation on eight goa...
متن کاملFetal Weight and Gender Estimation using Computer based Ultrasound Images Analysis
This paper proposes a fetal gender and weight estimation method using ultrasound images. Normally the gender and weight estimation is done by the physician through the observation only. The accuracy of the gender and weight estimation strongly dependent on the experiences of the physician as the images of ultrasound are not clear for those low cost two dimension (2D) ultrasound. In order to inc...
متن کاملUltrasound (in)accuracy: it's in the formulae not in the technique – assessment of accuracy of abdominal circumference measurement in term pregnancies
Introduction: Fetal abdominal circumference (AC) is utilised in calculations for the estimation of fetal weight (EFW) and has been proposed as a method of monitoring diabetic pregnancies. We evaluated true ultrasound accuracy by comparing fetal AC biometry with neonatal anthropometry and compared this with standard ultrasound estimations of fetal weight. Methods: A prospective observational stu...
متن کاملComment on the article "accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes".
OBJECTIVE Compare the accuracy and reliability of fetal heart rate identification from maternal abdominal fetal electrocardiogram signals (ECG) and Doppler ultrasound with a fetal scalp electrode. DESIGN Prospective open method equivalence study. SETTING Three urban teaching hospitals in the Northeast United States. SAMPLE 75 women with normal pregnancies in labor at >37 weeks of gestatio...
متن کاملUltrasound-guided induced fetal death, an alternative method for induction of abortion in the bitch
This study was performed to achieve abortion in a short time and with minimum side effects in a bitch, as an alternative method for termination of unwanted pregnancy. The experimentation was performed on 10 privately owned crossbred pregnant bitches, in their late second trimester of pregnancy, having a variable number of fetuses (3 to 9). Fetal death was induced by transabdominal intracardiac ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of perinatal medicine
دوره 8 2 شماره
صفحات -
تاریخ انتشار 1980