Comparison Study of Isceon 49 (A Drop-in Replacement for R12) with R12 and R134a
نویسنده
چکیده
Due to the undesirable environmental consequences ofR12, there is a great challenge to find a suitable substitute for Rl2. A new refrigerant blend Rl34a!R218/R600a (88'Yoi9'Yol 3%) called JSCEON 49 has been developed as a long term, zero ozone depletion-potential replacement for Rl2. A computer program was written to calculate the cycle characteristics, such as cooling capacity, coefficient of pe1jormance (COP), pressure ratio, system pressure and temperature, and compressor power for design and part-load pe1jormance which is also our base of comparison. A series of tests has been completed to validate the computer program and to study the behaviour of JSCEON 49. Experimental results indicate that the pe1jormance of a system does not degraded on using JSCEON 49, relative to that obtained with Rl2. The results of the computer program shows that Rl2 may be replaced by the new blend without a significant loss in overall performance. NOMENCLATURE p = Density (kg I m 3 ) 77 voi = Volumetric efficiency % a= Heat transfer coefficient (kW I m ° C) Q =Rate of heat transfer (kW) U =Overall heat transfer coefficient (kW I m o C) e = Heat exchanger effectiveness Subscripts c = Condenser e = Evaporator f =Refrigerant cc = Coolant in the condenser ce =Coolant in the evaporator cool = Coolant Vs = Compressor displacement ( cm ) N =Compressor speed (RPM) h = Enthalpy ( kJ I kg) m =mass flow rate (kg Is) T = Temperature ( ° C) A =Area (m ) ci = Condenser inlet co = Condenser outlet ei = Evaporator inlet eo =Evaporator outlet INTRODUCTION At the present time the preferred replacement refrigerant for R12 is HFC RI34a. This has thermophysical properties that compare well with those of R12 and more importantly it has zero ozone depletion potential. However, R134a is not a 'drop-in' replacement for R12 because there is a need to change the compressor lubricant and expansion valve. Changing over from R12 to R134a can therefore be an ex-pensive and time consuming procedure.
منابع مشابه
Discharge Gas Temperature Control in Reciprocating Hermetic Compressors Modified for R134a/R22 Refrigerants Operation as Substitutes of Present R12/R502
Discharge gas temperature value is an indicator of compressor safe operating conditions, particularly on R12 and R502 commercial applications. These refrigerants will be replaced very soon by R134a and R22 respectively, also if R22 is not considered a final solution. High discharge temperatures are typical in LBP-R22 hermetic compressors operating at low evaporating temperature as low as -40"C;...
متن کاملتأثیر نوع سیال عامل بر عملکرد سیستم تبرید اجکتوری
In this paper, the performance of an ejector cooling system and the effect of the following different working fluids such as water, ammonia, R134a, R141b, R12, R600 and R245fa are described and the effects of cycle parameters on the consumed heat and work and COP are studied. This cycle with the working fluid R141b has the least COP while the working fluid R₁₂ in comparison with the other worki...
متن کاملAnalysis of R134a Cabinets from the First Series Production in 1990
Series production of R134a compressors started in 1990. 200 compressors, from the very first series, were built into cabinets placed in an apartment house in Denmark. Cabinets with R12 compressors were placed in the same apartment house as well. The cabinets have two separate cooling systems; one for a cold cabinet and one for a freezer. 10 running cabinets were called back for analysis; 7 cabi...
متن کاملThermodynamic Analysis of Refrigerators Using Different Refrigerants
Refrigerants that are used in refrigeration systems, cause environmental difficulties such as depletion of ozone layer and greenhouse effect. Thus, we must find substitutes for such refrigerants, in this paper, the effect of refrigerant on the thermodynamics performance of refrigeration cycles are studied. To do this, a refrigerator that has designed for R12, is simulated. Results show that pur...
متن کامل